5.3.4 V.52 BER TEST GENERATOR

The Model 1090 has a built-in test pattern generator and detector. It can be invoked at both ends of a link simultaneously or it can be used with the Local Analog, Remote Digital or Local Digital Loopbacks. The following example requires two operators: one to initiate and monitor the test at the local Model 1090, and one at the remote Model 1090. To use the V.52 BER test by itself, both operators should simultaneously follow these steps.

A.Locate the 511/511E toggle switch on the front panel of the Model 1090 and move it DOWN. This activates the V.52 BER test mode and transmits a 511 pseudorandom test pattern to the other unit. If any errors are received, the receiving Model 1090’s red ER LED will blink sporadically.

NOTE: For this test to function, the 511 switch on both Model 1090’s must be on.

B.If the test indicates no errors are present, move the V.52 toggle switch UP, activating the 511/E test. The 511/E test transmits the 511 pseudorandom test pattern and injects intentional errors about once per second. If the test is working properly, the receiving Model 1090’s red ER LED will blink regularly.

A successful 511/E test will confirm that the link is in place, and that the Model 1090 built-in 511 generator and detector are working properly.

C.This test can be done by one operator by first activating the local analog loop or remote digital loop.

APPENDIX A

1090 SPECIFICATIONS

Transmission Synchronous

Format

Transmission Line: Unconditioned twisted pair 19 - 26 AWG

Clocking:

Internal, external or receive loopback

Distance:

Up to 11 miles (19 AWG @ 56 kbps)

Data Rates:

48, 56, 64, 72, 80, 112, 128, 144 and 160

 

kbps (switch selectable)

Carrier Control:

Constantly on or Controlled by RTS

RTS/CTS Delay:

No delay, short delay (4 - 9 mSec), long

 

delay (33 - 71 mSec).

Diagnostics:

V.52 compliant bit error rate pattern

 

(511/511E pattern) generator and detector

 

with error injection mode; V.54

 

compliant—local analog loopback and

 

remote digital loopback, activated by front

 

panel switch or via serial interface

LED Status

TD, RD, RTS, CD, DTR, ER and TM

Indicators:

(test mode)

Isolation:

Minimum 3000V RMS via transformers

Surge Protection:

600W power dissipation at 1 ms

DCE/DTE Interface:

Field-replaceable Quick ConnectTM

 

modules.

Twisted Pair

8-position modular jack (RJ-45)

Interface:

 

Power:

115/230 VAC (switch selectable), 50/60 Hz;

 

85 - 256 VAC, 50/60 Hz (universal input

 

option); 48 VDC (option). 5 watts.

Temperature

 

Range:

0-50°C (32-122°F)

Altitude:

0-15,000 feet

Humidity:

5 to 95% non-condensing

Dimensions:

7.3” x 6.6” x 1.62” (185mm x 168mm x

 

41mm)

Weight:

2.02 lbs. 1.0 Kg

17

18

Image 10
Contents User Manual CE Notice ServiceRadio and TV Interference Telephone 301 Email support@patton.comExternal DIP Switch Settings FeaturesDescription Switch SET S1 S1 Summary TableSignal Switch SET S2Twisted Pair Connection Using RJ-45 Connection to the Twisted Pair InterfaceConnection to the Serial Port Signal PIN#Changing Quickconnect Modules AC Power Connection Reconfiguring the X.21 Quickconnect ModuleConnection to the Power Source Connection to a DTE DeviceLED Status Monitors POWER-UPDiagnostics Local Analog Loopback LALRemote Digital Loopback RDL Local Digital Loopback LDLSpecifications 4 V.52 BER Test GeneratorAppendix C Factory Replacement Parts Accessories Wire Gauge Capacitance ResistanceAlways use twisted pair wire-this is not an option Cable RecommendationsPin # Signal 34F Connector-DCEDB-25F Connector-DCE Appendix DAppendix D Interface PIN Assignment Tables 34F Connector-DCE Interface Pin # SignalDB-25F Connector-DCE Interface Appendix D Interface PIN AssignmentDB-15F Connector-DCE Setting Interface