Patton electronic 4830 Series Changing the IP address, 172.16.40.1if-ipeth0#ipaddress 172.16.1.10

Page 5

SmartNode 4830 Quick Start Guide

3.Type administrator as the login prompt and press the Enter key after the password prompt (do not type anything for the password). A prompt will appear consisting of the IP address and > character.

login:administrator

password:

172.16.40.1>

4.Following log in, the SmartNode is in operator execution mode (indicated by > character in the command line prompt). With the commands enable and configure, you enter the configuration mode.

172.16.40.1>enable

172.16.40.1#configure

172.16.40.1(cfg)#

Changing the IP address

1.Select the context IP mode to configure an IP interface.

172.16.40.1(cfg)#context ip router

172.16.40.1(ctx-ip)[router]#

2.Set the IP address and network mask for the each IP interface (eth0, for example).

Note For the examples in this guide, a private network (172.16.1) IP address is used.

172.16.40.1(ctx-ip)[router]#interface eth0

172.16.40.1(if-ip)[eth0]#ipaddress 172.16.1.10 255.255.255.0

2002-10-29T00:09:40

: LOGINFO

: Link

down on interface eth0.

2002-10-29T00:09:40

: LOGINFO

: Link

up on interface eth0.

172.16.1.10(if-ip)[eth0]#

 

 

3.Make this modified configuration your new start-up configuration. On the next start-up the system will initialize itself using the modified configuration.

172.16.1.10(if-ip)[eth0]#copy running-config startup-config

172.16.1.10 (if-ip)[eth0]#

Go to section “Connecting the SmartNode to the LAN” on page 6 to connect the SmartNode to your network.

Connecting a PC, logging in, and configuring the LAN IP address

5

VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 600030

Image 5
Contents SmartNode 4830 Series Trademark Statement SmartNode product SmartNode 4838 shown IntroductionConnecting to a PC and logging Connecting power and configuring the default IP address172.16.40.1if-ipeth0#ipaddress 172.16.1.10 Changing the IP addressETH Connecting the SmartNode to the LANAdditional information Compliance Safety complianceRadio and TV Interference FCC Part EMC complianceIndustry Canada Notice FXO ports FCC Part 68 Acta Statement FXO portsEC Declaration of Conformity CE NoticeApproval EG-KonformitätserklärungZulassung Authorized European RepresentativeAuthorized European Representative