Patton electronic 4830 Series quick start Additional information

Page 7

SmartNode 4830 Quick Start Guide

Note If your application is unique and not covered by any of Patton’s configura- tion templates, you can manually configure the SmartNode instead of load- ing a configuration file template. In that case, refer to the SmartNode Series SmartWare Software Configuration Guide for information on configuring the SmartNode device.

In this example we assume the TFTP server on the host with the IP address 172.16.1.11 and the configuration named SN.cfg in the root directory of the TFTP server.

172.16.1.99(if-ip)[eth0]#copy tftp://172.16.1.11/SN.cfg startup-config

Download...100%

172.16.1.99(if-ip)[eth0]#

After the SmartNode has been rebooted the new startup configuration will be activated.

When you issue the reload command, the SmartNode will ask if you want to copy the running configuration to the startup con- figuration. Since you just downloaded a configuration file to the startup configuration you must answer this question with NO.

Otherwise, the downloaded configuration will be overwritten and lost!

172.16.1.99(if-ip)[eth0]#reloadRunning configuration has been changed.

Do you want to copy the 'running-config' to the 'startup-config'?

Press 'yes' to store, 'no' to drop changes : no

Press 'yes' to restart, 'no' to cancel : yes

The system is going down

Additional information

For detailed information about configuring and operating guidance, set up procedures, and troubleshooting, refer to the SmartNode Series SmartWare Software Configuration Guide and the SmartNode Getting Started Guide on the enclosed Patton VoIP CD-ROM or at http://www.patton.com/voip/. On the CD-ROM you will also find numerous freeware and shareware tools, including TFTP servers, Telnet clients, etc..

Additional information

7

VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 600030

Image 7
Contents SmartNode 4830 Series Trademark Statement SmartNode product SmartNode 4838 shown IntroductionConnecting to a PC and logging Connecting power and configuring the default IP address172.16.40.1if-ipeth0#ipaddress 172.16.1.10 Changing the IP addressETH Connecting the SmartNode to the LANAdditional information EMC compliance Safety complianceCompliance Radio and TV Interference FCC PartIndustry Canada Notice FXO ports FCC Part 68 Acta Statement FXO portsEG-Konformitätserklärung CE NoticeEC Declaration of Conformity ApprovalZulassung Authorized European RepresentativeAuthorized European Representative