LK5: Configuration Auto-Sense
This setting determines whether the host can automatically sense the configuration of the Applique. The operation of the Applique is not affected by this jumper setting.
LK5 | Setting |
Strap On | |
Strap Off |
LK6 & LK7: 75 Ohm Termination Impedance
This jumper sets the termination impedance correctly for 75 Ohm operation. Both jumpers must be in place when operating in 75 Ohm (unbalanced) mode. Conversely, both jumpers must be removed when operating in 120 Ohm (balanced) mode.
LK6 | LK7 | Setting |
On | On | 75 ohm operation |
Off | Off | 120 ohm operation |
3.3POWER SUPPLY OPTIONS
The Model 2703-X21 is available with three power supply options:
The Standard power supply option (Model
The Universal Interface power supply option (Model
The DC power supply option (Model
WARNING! There are no