Patton electronic 1004ABRC user manual LED Status Monitors, Power-Up

Page 11

5.0 OPERATION

Once you have configured each Model 1004ABRC and connected the cables, you are ready to operate the units. Section 5.0 describes the LED status monitors and the power-up procedure.

5.1 LED STATUS MONITORS

The Model 1004ABRC features front panel LEDs that indicate the condition of the modem and communication link. Figure 6 (below) shows the positions of the LEDs.

Model 1004RC

 

Power

 

TD

Unit

RD

A

 

CD

 

TD

Unit

 

B

RD

 

CD

Figure 6. The Model 1004ARC front panel, showing LED positions

The green “PWR” LED glows when power is applied to the modem through its mid-plane chassis connection.

The green “TD” and “RD” LEDs show positive state data activity. The red “TD” and “RD” LEDs show negative state data activity. A solid red light indicates an idle state.

The green “CD” LED lights when the receive carrier is detected; the red LED lights when the receive carrier is absent.

5.2POWER-UP

There is no power switch on the Model 1004ABRC: Power is auto- matically applied to the 1004ABRC when its card-edge connector touches the chassis’ mid-plane socket, or when the chassis’ power is turned on.

NOTE: The 1004ABRC is a “hot swappable” card—it will not be damaged by plugging it in or removing it while the rack is pow- ered up.

19

APPENDIX A

PATTON ELECTRONICS MODEL 1004ABRC

SPECIFICATIONS

Transmission Format:

Asynchronous

Data Rate:

0 to 115.2 Kbps

Surge Protection:

Silicon Avalanche Diodes

Control Signals:

DSR turns “ON” immediately after the termi-

 

nal raises DTR; DCD turns “ON” after re-

 

cognizing the receive signal from the line;

 

CTS turns on after the terminal raises RTS

Transmission Line:

2-wire or 4-wire, unconditioned twisted pair

Transmit Mode:

Full or half duplex

Transmit Level:

2V ± 10% differential output voltage

Carrier:

Controlled by data transitions

RTS/CTS Delay:

8 msec or zero

Echo Mode:

Echo and No Echo, supported in both

 

2-wire and 4-wire modes

Receiver Impedance:

Low (120 ohms), High (100k Ohms)

Line Connection:

RJ-11 or RJ-45 jack

Surge Protection:

Silicon Avalanche Diodes on twisted pair

 

interface from each line to frame ground

Power Supply:

Rack-mount power supply is switchable

 

between 120V and 240V AC; rack chassis

 

supplies 10V AC to the Model 1004ABRC,

 

typical consumption is 700 mW per card

Fuse:

400mA for 120V applications; 200mA for

 

240V applications

Temperature Range:

0-50°C (32-122°F)

Altitude:

0-15,000 feet

Humidity:

Up to 95% non-condensing

Dimensions:

0.95”w x 3.1”h x 5.4”l

 

20

Image 11
Contents User Manual Radio and TV Interference SectionDescription ServiceFeatures CE NoticeSwitch SET S1 Front Card ConfigurationSwitch Settings Modem a Switch SET S3 Switch SET S2Switch Settings Modem B Switch SET S4 Sgnd & Frgnd JB5 Rear Card ConfigurationRear Card Strap Settings Interface Card Strap Summary Table #1Model 1000R16 Rack Chassis Rack Power SupplyDTE as DSR or RI JB6 & JB7 Twisted Pair Connection Installing the Model 1004ABRC Into the ChassisSignal RS-232 ConnectionHost First Slave Second Slave Signal PIN#Signal PIN# XMT+ Multipoint Twisted Pair ConnectionLED Status Monitors POWER-UPPatton Electronics Model 1004ABRC Specifications Patton Model # Description Wire Gauge Capacitance ResistancePatton Electronics Model 1004ABRC Factory Replacement Parts Cable RecommendationsPatton Electronics Model 1004ABRC Interface PIN Assignments Patton Modular Interface 10 Wire RJ-45