1.0 WARRANTY

Patton Electronics warrants all Model 515 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment. This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.

1.1 SERVICE AND SUPPORT

All warranty and nonwarranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Support: (301) 975-1007; http://www.patton.com; or, support@patton.com.Notice: Packages received without an RMA number will not be accepted.Patton Electronics' technical staff is also available to answer any questions that might arise concerning the installation or use of your Patton Model 515. Technical Service hours are 8AM to 5PM EST, Monday through Friday.

1.2 CE NOTICE

The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the Union European (EU). A Certificate of Compliance is available by contacting Technical Support.

2.0 GENERAL INFORMATION

Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for One Year parts and labor. If any questions arise during installation or use of the unit, contact Patton Electronics Technical Support: (301) 975-1007; http://www.patton.com; or, support@patton.com.

3.0 PRODUCT DESCRIPTION

The Patton Model 515 DB-15 Surge Protector employs a solid state hybrid network to guard DB-15 data ports against data loss and hardware damage due to transient surges. Equipped with one male and one female DB-15 connector, the Model 515 inserts between the data cable and DB-15 port. The Model 515 intercepts data line transients and sends them directly to chassis ground through the metal D-shell.

Three versions of the Model 515 are available: The Model 515/25 clamps at 18 volts, protects all 15 pins, and is designed for use with RS-232 interfaces. The Model 515/6 clamps at 7.5 volts, protects all 15 pins, and is designed for use with RS-422, RS-423 and RS-485 interfaces. The Model 515/T1 clamps at 7.5 volts, protects pins 1, 3, 9 and 11, and is designed for use with T1 equipment. All three versions provide up to 1500 Watts of transient protection.

Warning: This product will not provide complete protection should your equipment or building be subject to a direct lightening hit.

4.0 SURGE PROTECTION BENEFITS

The method of surge protection used in the Model 515 adds four benefits to your system:

High Surge Capacity The Model 515 handles up to 1500 Watts of surge energy without failure.

Quick Response The Model 515 has fast response times (1 pS at the component level; 0.5 µS installed). Transient surges are clamped at 18V for RS-232 and 7.5V for RS-422/423/485, and 7.5V for T1 equipment.

Low Impedance The Model 515 adds minimal load to your system. It is about the same as a gender changer.

Open Failure The Model 515 fails “open” if your system experiences a severe transient or power fault above the rated voltage of the protector. This means that data and surge energy is shunted directly to chassis ground, rather than being allowed to flow throughout the system.