3.2.4 Unit Options

The Unit Options screen looks like this (factory default):

aHeader Line 1 & Header Line 2

Headers 1 and 2 are provided for easy identification of your unit after installation. You may want to give each unit a unique name via the header lines to help distinguish one unit from another. You can enter a header up to 40 letters long. Two lines provide 80 letters for your use. That’s a lot of flexibility!

bPassword

The Password facility provides security by allowing only those who know the correct password to configure the unit via the control port. You can still configure the unit via the DIP switches. The password can be up to 16 characters long, with no restriction on the combination of characters you can use, so be sure to remember the password. If you lose your password, you will lose the ability to access the unit via the control port.

cLoop Timeout

The Loop Timeout setting can be set to one of the following:

00:05 =

five minutes

00:10 =

ten minutes

00:15 =

fifteen minutes

00:30 =

thirty minutes (default setting)

00:45 =

forty-five minutes

01:00 =

one hour

01:30 =

90 minutes

02:00 =

two hours

03:00 =

three hours

NEVER =

forever—the unit will remain in loopback without user

 

intervention.

dSet to Default Configuration

You may set the NetLink-T1™ to its factory default configuration, except for the header lines and the password, by executing the Set to Default Configuration command.

eService Information

If you need to contact us for help, you can view the Service Information screen. Here is what it looks like:

29

30

Image 16
Contents User Manual Table of Contents Warranty StatementGeneral Information CE NoticeRadio and TV Interference FCC InformationFCC Compliance Industry Canada NoticeService Information FeaturesTel 301 Email support@patton.com Monday through FridayConfiguration DIP Switch ConfigurationSupported Applications 2710 as the Interface between the Telco and CPESwitch SET Summary Table Switches SW1, SW2, and SW3Switch SW4 Line Framing and Coding Line Framing OptionsSwitch SW6 Clock Mode Switches SW7 and SW8 Line Build OutSoftware Configuration VT100Introduction to Main Menu Helpful HintsSystem Configuration Line FormatESF default Options ESF, D4, UnframedLine Coding B8ZS default Options AMI, B8ZS, B7ZS DS0 Line Rate 64kbps default Options 64kbps, 56kbpsOptions Network, Internal, External ESF Carrier Loops Enabled default Options Enabled, DisabledESF Data Link Ansi T1.403 Options Ansi T1.403, AT&T TR54016 54 Loops Enabled default Options Enabled, Disabled Default Config Source Eeprom Option EEPROM, SwitchSystem Diagnostics Local Loop Idle defaultRemote Loop Idle default SpacebarTest Pattern Idle default Options Idle or Sending Error Insertion Off default Options On, OffSelected Pattern NI StatusError Counters Current DIP Switch SettingsValid Interval Count & Current Interval Time Rx PRMPassword Loop TimeoutSet to Default Configuration Service InformationDTE Interface Connection Power ConnectionNetwork Interface Connection LED Descriptions TXDRXD LOSLoop V.54 & Telco Diagnostics Operating Local Loopback LLOperating Remote Digital Loopback RL Central Office LoopsPatton NETLINK-T1 Model Specifications BIT Error Rate V.52 DiagnosticsQrss Patton NETLINK-T1 Model Cable Recommendations Wire Gauge Capacitance ResistancePatton Model # Description Patton NETLINK-T1 Model Interface PIN Assignment Jumper Position for Power via DC Power Jack default Patton NETLINK-T1 Model Power Supply InterfaceJumper Position for Power via Pin KK

2710 specifications

The Patton Electronic 2710 is a versatile IoT (Internet of Things) device that has garnered attention for its robust capabilities in facilitating reliable communication and seamless data transmission. Tailored for various industrial applications, this product stands out with its blend of cutting-edge technologies and practical features, making it an essential tool for businesses looking to enhance their connectivity infrastructure.

One of the main features of the Patton 2710 is its multi-interface support. This device is equipped with a variety of ports, including serial interfaces like RS-232, RS-485, and RS-422, as well as Ethernet and USB connectivity options. This versatility allows it to connect seamlessly with different devices and systems, from legacy equipment to modern networked devices, enabling efficient data exchange and communication across a variety of protocols.

The Patton 2710 also boasts robust protocol support, including various telecommunications and networking protocols such as TCP/IP, UDP, and SNMP. This extensive compatibility ensures that it can operate effectively in diverse environments, whether in a factory setting monitoring machinery or in a smart city application controlling infrastructure systems. With its support for these protocols, users can implement advanced monitoring and management solutions, improving operational efficiency and reducing downtime.

In terms of technology, the Patton 2710 features advanced security measures that safeguard the integrity of the data being transmitted. With built-in encryption and secure communication protocols, users can rest assured that their sensitive information remains protected against potential cyber threats. This is increasingly important in today's digitally interconnected landscape, where data breaches can have serious repercussions.

The device is also designed for ease of use and installation. Its intuitive web-based management interface simplifies configuration and monitoring, allowing users to set up the device quickly without extensive technical knowledge. This user-friendly design empowers organizations to implement the device across their operations with minimal training and support.

Another significant characteristic of the Patton 2710 is its rugged build quality. Designed to withstand harsh industrial environments, the device is often housed in enclosures that protect it from dust, moisture, and extreme temperatures. This durability ensures that it can operate reliably in demanding conditions, making it suitable for a wide range of industries, from manufacturing to transportation.

In summary, the Patton Electronic 2710 stands out as a powerful tool for enhancing connectivity and facilitating IoT applications. With its multi-interface capabilities, robust protocol support, advanced security features, user-friendly design, and rugged build, it provides businesses with the reliable solutions they need to thrive in an increasingly connected world.