Model 3088A Series Getting Started Guide

B • Specifications

 

 

Terminal (Green)

The Terminal LED glows solid under the following circumstances:

3088A/CA with V.35 interface and 3088A/A with RS-232 interface: if the serial interface has asserted

DTR

3088A/D with the X.21 interface

-Configured as DCE: Indicates that the “Control” signals have been asserted.

-Configured as DTE: Indicates that the “Indication” signals have been asserted

TM/ER (Yellow)

The Test Mode/Error (TM/ER) LED is used to indicate that a test mode is in progress or an error has been detected. It blinks once every second while a test mode is starting. It glows solid while a test mode is in progress. It blinks once if an error is detected either during a test mode, or in normal DSL operation.

LOS (Red) [Model /K]

The LOS LED blinks once per second to indicate either framing errors or clock slips. Clock slips are often caused by a mis-configured clock mode.

Link (Green)

The Link LED shows that there is an active physical connection to the Console.

Activity (Green)

The Activity LED shows that there is data being transferred through the Console connection. During a soft- ware upgrade procedure, if the Activity LED is on for an unusually long time, there is a problem with the upgrade, and the device should be restarted. The TFTP server should be checked (normal upgrades take about 10 seconds on a 100mbit link).

Configuration

Configuration is done with either externally accessible DIP switches, CLI or through the EOC (Embedded Operations Channel) from a Model 3096RC G.SHDSL concentration card.

Power and power supply specifications

The CPE comes with either an AC or DC power supply:

The supply’s connection to the CPE is a 2.5 mm barrel receptacle with the center conductor positive.

There is one fuse in the equipment rated at 250V, 500 mA, 2 sec.

Rated voltage: 5 VDC

Rated current: 1 A DC

Configuration

60

Image 60
Contents SHDSL.bis CPE with fixed serial interface Mailsupport@patton.com Summary Table of Contents Table of Contents Software Upgrade Compliance information Factory default values for software-configurable parameters List of Figures List of Tables About this guide AudienceStructure Precautions Impaired functioningSafety when working with electricity Typographical conventions used in this document General observationsGeneral conventions Convention MeaningChapter contents General informationFeatures OnSite 3088A overviewSerial interface types Power input connector External AC universal power supplyExternal 48 VDC power supply Configuration Software CLI configuration Hardware DIP-switch configurationIntroduction Lists the Model 3088A’s configurable parameters Parameter Description Possible ValuesConfiguring the DIP switches System reset mode DIP switch settingsPosition Function CA, /D models Models Position FunctionS4-2 through S4-8 Data Rate S4-2 S4-3 S4-4 S4-5 S4-6 S4-7 S4-8 Data Rate kbps2240 DCE/DTE operation ModeClock Source Ethernet Management Port DSL Line Condition Good or Poor Help Commands System Configuration CommandsSystem Status Commands DSL Configuration Commands DSL Status CommandDSL Clear Errcntrs Command E1 Configuration CommandsExample Command Line Interface Session Remote Console3088A System set circuitid 3088A/K Circuit ID OnSite Plug ‘n’ Play 3088AOnSite installation Installation Connecting the twisted pair interfaceConnecting the Model 3088A serial interface Connecting the Model 3088A to a DCE or DTE deviceConnecting the Model 3088A/K serial interface Connecting the Model 3088A/K to an E1 NetworkConnect twisted pair 120 ohm to E1 network Connecting dual coaxial cable 75 ohm to E1 network DSLConnecting power External AC universal power supplyDC Power To Power Supply JackOperation Power-up Power GreenLED status monitors DSL GreenTest modes Local Analog Loopback diagram PatternsRemote console operation How to Connect Establishing a Remote Console SessionHow to Disconnect Log in to 3088 Near EndDifferences in Local and Remote Control Session Behavior Remote control session with LAL diagramSoftware Upgrade Software Upgrade Reset configuration to factory defaults Reset configuration to factory defaults Contacting Patton for assistance Warranty coverage Contact informationPatton support headquarters in the USA Out-of-warranty service Returns for creditReturn for credit policy RMA numbersAppendix a Compliance information Safety ComplianceRadio and TV Interference FCC Part CE Declaration of ConformityAppendix B Specifications Serial connector DiagnosticsClocking modes DTE rateConfiguration Power and power supply specificationsTransmission line Line codingLine rates DSL line Line interfaceShdsl physical connection EnvironmentAppendix C Factory default values Factory default values for software-configurable parameters Parameter Default valueHDB3 Appendix D Factory replacement parts and accessories Factory replacement parts and accessories Power SuppliesPower Adapters Appendix E Interface pinouts Pin # Signal Pin # Signal Designation SourceLine port RS-232 interfaceInterface E1 interfacePin Signal Ethernet Console port
Related manuals
Manual 8 pages 13.2 Kb

3088A specifications

The Patton Electronics 3088A is a highly versatile and robust device designed to facilitate seamless communications over long distances using various transmission mediums. This model exemplifies the pinnacle of technology in the realm of serial-to-Ethernet devices, serving a multitude of applications in modern networking environments.

One of the standout features of the 3088A is its ability to convert RS-232, RS-422, and RS-485 serial signals into Ethernet TCP/IP data packets, allowing for the integration of legacy systems with contemporary Ethernet networks. This feature is crucial for businesses looking to modernize their infrastructure without discarding existing equipment that operates on serial protocols.

The 3088A boasts an impressive transmission range, which makes it suitable for both industrial and commercial applications. It supports data rates of up to 115.2 Kbps, ensuring that data can be transmitted quickly and efficiently. Additionally, with a built-in web server and a user-friendly interface, configuration and management become straightforward tasks, reducing the complexity often associated with network setups.

Another vital feature of the 3088A is its compatibility with various communication protocols, including TCP, UDP, and ARP. This flexibility ensures that it can be integrated into a wide range of network configurations, catering to specific application requirements, from simple point-to-point communication to complex networking setups.

The device also incorporates advanced security features, such as support for secure socket layer (SSL) connections, to safeguard data transmission against unauthorized access and potential threats. This is particularly important in environments where sensitive information is being transmitted, providing peace of mind for organizations concerned about data integrity and security.

Furthermore, the Patton 3088A is designed with durability in mind. It features a compact and rugged enclosure suitable for deployment in harsh environments, making it ideal for field operations and various industrial applications. The device supports wide power input ranges, ensuring operational stability regardless of fluctuating power conditions.

In summary, the Patton Electronics 3088A stands out as a reliable and efficient solution for those seeking to bridge the gap between serial and Ethernet communications. Its high-speed data transmission capabilities, extensive compatibility with various protocols, enhanced security features, and rugged design make it an essential tool for modern networking needs, enabling businesses to evolve while maximizing their existing technologies.