Patton electronic 3040/V35 manual SW15-5 SW15-6 SW15-7 SW15-8 Rate HS Opt

Page 13

PATTON ELECTRONICS CO.

3040/V35

INSTALLATION AND OPERATIONS MANUAL

139001UA

SW15-5 SW15-6 SW15-7 SW15-8

Rate

ON

ON

ON

ON

HS Opt.

 

 

 

 

 

OFF

ON

ON

ON

768K

 

 

 

 

 

ON

OFF

ON

ON

384K

 

 

 

 

 

OFF

OFF

ON

ON

192K

 

 

 

 

 

ON

ON

OFF

ON

128K

 

 

 

 

 

OFF

ON

OFF

ON

72K

 

 

 

 

 

ON

OFF

OFF

ON

64K

 

 

 

 

 

OFF

OFF

OFF

ON

57.6K

 

 

 

 

 

ON

ON

ON

OFF

56K

 

 

 

 

 

OFF

ON

ON

OFF

48K

 

 

 

 

 

ON

OFF

ON

OFF

38.4K

 

 

 

 

 

OFF

OFF

ON

OFF

28.8K

 

 

 

 

 

ON

ON

OFF

OFF

19.2K

 

 

 

 

 

OFF

ON

OFF

OFF

14.4K

 

 

 

 

 

ON

OFF

OFF

OFF

9.6K

 

 

 

 

 

OFF

OFF

OFF

OFF

4.8K

 

 

 

 

 

For the High Speed Option set SW15-5, 6, 7 and 8 to ON and select the desired rate by installing JP4 for 2048K, JP5 for 1024K, JP6 for 512K or JP7 for 256K. Only one of the four jumpers should be installed of proper operation.

Fallback Clock Enable (SW16-7)

If Clock Fallback is required when the primary clock fails, set switch SW16-7 to OFF. If Fallback is not required set SW16-7 to ON. The Fallback clock rate is selected with the internal baud rate option. When the Fallback is activated the FBC LED will illuminate.

Fallback Clocking From Sub-Channel 4 (SW16-8)

To use the Sub-Channel 4 RX Clock as the Fallback clock set SW16-8 to OFF. To use the Internal Baud Rate Clock as the Fallback clock set SW16-8 to ON.

Fallback Mode Selection (SW16-6)

If Fallback is required, two modes are available via switch SW16-6. To Fallback when the transitions from the primary clock source stop, set SW16-6 to ON. To Fallback when DCD on Sub-Channel 1 becomes inactive, set SW16-6 to OFF.

2-5

SETUP & INSTALLATION

Image 13
Contents 3040/V35 Copyright Notice Emission Requirements Contents 3040/V35 3040/V35 3040/V35 3040/V35 Switch 16 All to on JP4 Thru JP7 Open OFF SW15-3 SW15-4 Clocks SW15-5 SW15-6 SW15-7 SW15-8 Rate HS Opt Internal Must Be Selected For DCE Channel Jumper 35 DSU/CSU DB-25 Channel Port is a DTE Master Port is a DCE Channel Port is a DTE Technical Specifications On DB-25 Sales 301 975-1000 Support 301