Patton electronic 3040/V35 manual JP4 Thru JP7 Open

Page 10

PATTON ELECTRONICS CO.

3040/V35

INSTALLATION AND OPERATIONS MANUAL

139001UA

Switch 18 - 1, 2, 3, 7 and 8 to OFF, 4, 5 and 6 to ON

Anti-Stream timer = 2 M bits

Anti-Stream = Disabled

Broadcast Data to Sub-Channels

RX Clock Source = Master

JP4 Thru JP7 Open

HS Option Not Enabled

JP8 thru JP12 to Open

DTR / DSR Not Forced

JP1 Thru JP3 to Installed

Factory Test Jumpers

If the system application requires one or more of the default settings to be changed, it will be necessary to remove the top cover of the enclosure to access and change the DIP switches located on the printed circuit board.

Disassembly

Remove the top cover by removing the phillips head screws located on the left and right sides of the 3040/V35 (CTS MD-V.35/TCB). DTE/DCE switches SW5 through SW14, baud rate Jumpers JP4 through JP7, interface Jumpers JP8 through JP12 and configuration switches SW15 through SW18 are located on the PCB as indicated on the strapping guide in the Appendix of this manual. After the switch selection activity is completed, re-install the top cover BEFORE connecting to a AC power source.

Installation

Select an appropriate location accessible to and within six feet of an AC power outlet, the outlet must have a ground pin receptacle for product warranty. The DCE-to-DTE cabling between each attached device and the 3040/V35 (CTS MD-V.35/TCB) should be “Straight Through”, shielded and terminated with male connectors. Sub-Channels are marked PORT 1 through PORT 4, the Master Port is marked, MASTER DCE/DTE. If any terminal has a priority service mode, ensure it is connected to the port connector designated “PORT 1” on the rear panel of the 3040/V35 (CTS MD-V.35/TCB). Secure other terminals or Modems to be serviced to the remaining “PORT” connectors. Connect the MODEM or TERMINAL to the connector designated “MASTER DTE/DCE”.

SETUP & INSTALLATION

2-2

Image 10
Contents 3040/V35 Copyright Notice Emission Requirements Contents 3040/V35 3040/V35 3040/V35 3040/V35 Switch 16 All to on JP4 Thru JP7 Open OFF SW15-3 SW15-4 Clocks SW15-5 SW15-6 SW15-7 SW15-8 Rate HS Opt Internal Must Be Selected For DCE Channel Jumper 35 DSU/CSU DB-25 Channel Port is a DTE Master Port is a DCE Channel Port is a DTE Technical Specifications On DB-25 Sales 301 975-1000 Support 301