NTI XTENDEX Wall Mount Extenders
LIMITATIONS
•
•The audio input of the XTENDEX is compatible with the following standard CPU audio outputs:
•Line out - typically lime green in color
•Speaker out- typically orange in color
•Headphone out- typically located on the
•The audio output of the XTENDEX is compatible with
PREPARATION FOR INSTALLATION
•Locations should be chosen for the monitors and speakers that also have space to connect the Remote Unit within the distance provided by the cables. If extension cables are needed, contact NTI for the cables required.
•The CAT5 cables must be run to the locations where the Remote and Local Units will be connected. Be careful to route the cables away from any sources of magnetic fields or electrical interference that might reduce the quality of the video signal (i.e. AC motors, welding equipment, etc.).
•All cables should be installed in such a way that they do not cause stress on their connections to the equipment. Extended lengths of cable hanging from a connection may interfere with the quality of that connection. Secure cables as needed to minimize this.
•Properly shut down and disconnect the power from the CPU, monitors, and speakers to be separated. If other equipment is involved whose connections are being interrupted, be sure to refer to the instruction manuals for that equipment for proper disconnection and
Note: CAT5 connection cable used between NTI XTENDEX Series Local and Remote or any XTENDEX Series products should not be run underground, outdoors or between buildings.
!WARNING: Outdoor or underground runs of CAT5 cable could be dangerous and will void the warranty.
CAT5 cable
Remote Unit
Local CPU
Local Unit
VGA
Monitor
AC
Adapter
Remote Monitor and
Stereo Speakers
VGA
Monitor
Local Monitor and Stereo Speakers
Typical Application