QuickSpecs
HP 3PAR StoreServ 7000 Storage
Technical Specifications
|
| 750 W (at 200 to 240 VAC) |
|
| For 460 W Power Supply: |
|
| 460 W (at 100 to 120 VAC), |
|
| 460 W (at 200 to 240 VAC) |
| Maximum Peak Power | For 1200 W Power Supply: |
|
| 800 W (at 100 VAC), |
|
| 900 W (at 120 VAC), |
|
| 1200 W (at 200 to 240 VAC) |
|
| For 750 W Power Supply: |
|
| 750 W (at 100 to 120 VAC), |
|
| 750 W (at 200 to 240 VAC) |
|
| For 460 W Power Supply: |
|
| 460 W (at 100 to 120 VAC), |
|
| 460 W (at 200 to 240 VAC) |
System Inlet Temperature | Operating | 10° to 35°C (50° to 95°F) at sea level with an |
|
| altitude derating of 1.0°C per every 304.8 m |
|
| (1.8°F per every 1000 ft) above sea level to a |
|
| maximum of 3048 m (10,000 ft), no direct |
|
| sustained sunlight. Maximum rate of change is |
|
| 10°C/hr (18°F/hr). The upper limit may be limited |
|
| by the type and number of options installed. |
|
| System performance may be reduced if operating |
|
| with a fan fault or above 30°C (86°F). |
| ||
|
| change is 20°C/hr (36°F/hr). |
Relative Humidity | Operating | 10% to 90% relative humidity (Rh), 28°C (82.4°F) |
| maximum wet bulb temperature, non- | |
|
| condensing. |
| 5% to 95% relative humidity (Rh), 38.7°C | |
|
| (101.7°F) maximum wet bulb temperature, non- |
|
| condensing. |
Altitude | Operating | 3048 m (10,000 ft). This value may be limited by |
|
| the type and number of options installed. |
|
| Maximum allowable altitude change rate is 457 |
|
| m/min (1500 ft/min). |
| 9144 m (30,000 ft). Maximum allowable altitude | |
|
| change rate is 457 m/min (1500 ft/min). |
Acoustic Noise | Listed are the declared | |
| average bystander position | |
| the product is operating in a 23°C ambient environment. Noise emissions were | |
| measured in accordance with ISO 7779 (ECMA 74) and declared in accordance | |
| with ISO 9296 (ECMA 109). The listed sound levels apply to standard shipping | |
| configurations. Additional options may result in increased sound levels. | |
| NOTE: The Listed sound levels apply to standard shipping configurations. | |
| Additional options may result in increased sound levels. | |
| Idle |
|
|
|
|
DA - 14433 North America — Version 17 — December 10, 2013 | Page 47 |