INSTALLATION INFORMATION: POWER HANDLING AND GROUNDING

For your safety, we have incorporated a 3-wire line (mains) cable with proper grounding facilities. It is not advisable to remove the ground pin under any circumstances. If it is necessary to use the equipment without proper grounding facilities, suitable grounding adapters should be used. Less noise and greatly reduced shock hazard exists when the unit is operated with the proper grounded receptacles.

ARCHITECTURAL AND ENGINEERING SPECIFICATIONS

The power amplifier shall have one input with provisions for balanced and unbalanced signals via terminal strip. A

600 ohm balanced line output shall be provided, also via terminal strip. The amplifier shall be capable of delivering

150 watts into 4 ohms at the 25 volt line output, and 150 watts into 33 ohms at the 70 volt line output. This unit shall have the capability of continuously operating if the AC mains are lost, due to its battery backup circuit (the battery must be provided). This amplifier shall be compatible with Peavey’s MediaMatrix system, providing a jack for easy hook up and operation. This amplifier must have a signal-to-noise ratio of at least 100 dB below rated output. The unit shall be called the Peavey Architectural Acoustics Division model IDC™ 150T II.

LIMITED WARRANTY

Peavey Electronics Corporation warrants to the original purchaser of this new Architectural Acoustics product that it is free from defects in material and workmanship. If within one (1) year from date of purchase a properly installed product proves to be defective and Peavey is notified, Peavey will repair or replace it at no charge. (Note: Batteries and patch cords not covered.) “Original purchaser” means the customer for whom the product is originally installed.

Damage resulting from improper installation, interconnection of a unit or system of another manufacturer, accident or unreasonable use, neglect or any other cause not arising from defects in material and workmanship is not covered by this warranty. The warranty is valid only as to products purchased and installed in the United States and Canada.

THIS LIMITED WARRANTY IS IN LIEU OF ANY AND ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR USE. UNDER NO CIRCUMSTANCES WILL PEAVEY BE LIABLE FOR ANY LOST PROFITS, LOST SAVINGS, INCIDENTAL DAMAGES OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THE PRODUCT, EVEN IF PEAVEY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. THIS LIMITED WARRANTY IS THE ONLY EXPRESSED WARRANTY ON THIS PRODUCT, AND NO OTHER STATEMENT, REPRESENTATION, WARRANTY, OR AGREEMENT BY ANY PERSON SHALL BE VALID OR BINDING UPON PEAVEY.

Peavey’s liability to the original purchaser for damages for any cause whatsoever and regardless of the form of action is limited to the actual damages up to the greater of Five Hundred Dollars ($500) or an amount equal to the purchase price of the product that caused the damage or that is the subject of or is directly related to the cause of action. This limitation of liability will not apply to claims for personal injury or damage to real property or tangible personal property alleg- edly caused by Peavey’s negligence. For information on service under this warranty, call a Peavey customer service representative at (601) 483-5376.

5

Image 5
Contents Cover for IDC 150T Page Power LED Indicators Mains 2 & 24 V DC Front Panel Features SPS LED IndicatorAC Power Switch DC Power SwitchDC Power Connector Back Panel FeaturesInput Sensitivity Controls Amplifier InputsLimited Warranty Installation Information Power Handling and GroundingArchitectural and Engineering Specifications Specifications Page Important Safety Instructions