Operating the
5.Press the LOCK button.
The INPUT buttons blink in sequence until the EDID is acquired.
To reset to the default EDID, disconnect the outputs and repeat the above steps.
7.2Storing and Recalling a Setting
You can use the STO and RCL buttons to store the current setup and then recall it.
To store a setting:
1.Set the machine to the desired setting.
For example, press INPUT SELECTOR button 3 on the TO OUTPUT 1 line and INPUT SELECTOR button 1 on the TO OUTPUT 2 line.
2.Press the STO button.
The STO button is illuminated and the selected inputs1 blink.
3.Press the STO button again2 to store the current setup.
The STO button no longer illuminates and the current setting is stored in the machine’s
To recall a setup:
1.Press the RCL button.
The RCL button illuminates as well as the current setting input buttons, and the input buttons of the stored setup blink.
2.Press the RCL button once again2 to recall the stored setting.
1 INPUT SELECTOR button 3 on the TO OUTPUT 1 line and INPUT SELECTOR button 1 on the TO OUTPUT 2 line 2 You have to press the STO button within 10 seconds, before the store operation times out
12 | KRAMER: SIMPLE CREATIVE TECHNOLOGY |