KTI Networks KGD-600 manual Ingress Settings

Page 37

4.6.3.2 Ingress Settings

Configuration

Description

 

 

Port

Port number

Tag Aware

Check tag data for every received packet

 

Tag-aware- set to activate Tag-based mode

 

Tag-ignore- set to use port-based mode and ignore any tag in packet

Keep Tag

Tag is removed from the received packet if exists

 

Enable - set to activate tag removal for VLAN-tagged packets

 

Disable - set to disable tag removal function

Drop Untag

Drop all untagged packets and priority-tagged packets

 

Enable - drop untagged packets and priority-tagged packets

 

Disable - admit untagged packets and priority-tagged packets

Drop Tag

Drop all VLAN-tagged packets

 

Enable - drop VLAN-tagged packets

 

Disable - admit VLAN-tagged packets

 

 

[Apply]

Click to apply the configuration change

[Refresh]

Click to refresh current configuration

[Back]

Click to go back to upper menu

 

 

Note:

1.Priority-tagged packet (VID=0) is treated as untagged packet in the switch.

2.[Tag Aware] setting affects the index used for VLAN classification (VLAN table lookup). The following table lists the index used:

 

Ingress [Tag Aware] setting

Received packet type

Tag-ignore

Tag-aware

Untagged

PVID

PVID

Priority-tagged (VID=0)

PVID

PVID

VLAN-tagged (VID>0)

PVID

Packet tag VID

3. Both [Drop Untag] and [Drop Tag] are set to Disable to admit all packets.

-37-

Image 37
Contents KGD-600 Page Trademarks Table of Contents Appendix. Factory Default Settings Plug and Play Quality of ServiceFiber Connectivity Web ManagementIndustrial Features FeaturesBasic functions Management functionsProduct Panels Specifications LED IndicatorsSoftware Management Functions DC Power InputMechanical EnvironmentalMounting the Switch on a Wall Safety CautionsUnpacking Din-Rail Mounting Panel Mounting Using Terminal Blocks Applying PowerUsing DC Power Jack Reset ButtonOperation Function Making UTP Connections Port Configuration ManagementNetwork Cables Auto MDI/MDI-X FunctionConnecting Fiber Cables Installing SFP Fiber TransceiverMaking Fiber Connection LED Indication Configuring IP Address and Password for the SwitchFunction State Interpretation #of bits Frame field AbbreviationUser priority Pvid Port VIDQoS Function Packet Priority Classification Egress Service PolicyPriority Class Queues Keep Tag Per port setting 2.1 802.1Q Tag Aware Per port settingVlan Function Vlan OperationDrop Tag Per Port Setting Drop Untag Per Port SettingIngress Default Tag Per Port Setting Packet Tag InformationVlan Classification Vlan Group Table ConfigurationPacket Forwarding Egress Tagging Rules Egress SettingsSummary of Vlan Function 802.1X Authentication Port Access Control Start Browser Software and Making Connection Login to the Switch UnitWeb Browser Set IP Address for the System UnitMaintenance ConfigurationMain Management Menu MonitoringSystem Configuration DescriptionSummary of the rules Management VlanPorts Configuration FunctionVLANs Vlan Configuration DescriptionPort-based Vlan Mode Mode Operation Port-based Vlan ISP ModeExample Advanced Vlan Mode Ingress Default Tag Ingress Settings Received packet type Tag Aware =Tag-ignore Vlan Groups Switch Vlan Mode selection Important Notes for Vlan ConfigurationDouble Tagged in Advanced Vlan Mode QoS Configuration Description Quality of ServiceClass 3 ~ Class 1 802.1p MappingDscp Mapping Weighted ratio priority Class 3210 = 1111 weighted ratio QoS Service PolicyPort Mirroring Radius IP 802.1X Configuration1 802.1X Re-authentication Parameters Statistics Restore Default Reboot SystemUpdate Firmware / Configuration Update FirmwareBackup Configuration File Upload Configuration FileLogout Ports Configuration System ConfigurationVlan Configuration Port-based Vlan Mode settingQoS 802.1p Mapping Quality of Service ConfigurationPort Mirroring Configuration QoS Service Policy802.1X Configuration QoS Dscp Mapping
Related manuals