C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com
Reg. 00 |
|
|
|
|
|
|
| Status |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Bit | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
Write |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Read |
|
|
| Not Used |
|
|
| BUSY |
|
| Not Used |
|
| RIRQ |
BUSY Relay Busy 1 (0 = relay is busy, not stable yet (busy for 16mS after Relay Register is written)) RIRQ Relay Interrupt 2 (1 = interrupt pending)
Notes:
1.This BUSY bit is
2.Reading this register does not clear a pending interrupt (RIRQ).
Reg. 02 |
|
|
|
|
|
|
| Control |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Bit | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
Write |
|
|
|
|
|
| Not Used |
|
|
|
|
|
| REN | SRST | |
Read |
|
|
|
|
|
| Not Used |
|
|
|
|
|
| REN | SRST | |
|
| REN | Enable Relay Interrupt (1 = enables relay interrupt (after BUSY timer)) |
|
|
| ||||||||||
| SRST | Soft Reset (1 = initiates a soft reset) |
|
|
|
|
|
|
|
| ||||||
Reg. 04 |
|
|
|
|
|
|
| Interrupt |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Bit | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
Write |
|
|
|
|
|
|
| Not Used |
|
|
|
|
|
|
| |
Read |
|
|
|
|
|
|
| Not Used |
|
|
|
|
|
|
| RIRQ |
RIRQ Relay Interrupt (1 = interrupt pending)
Note: Reading this register clears a pending interrupt.
Reg. 14 |
|
|
|
|
|
|
| Relay |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Bit | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
Write |
|
|
|
|
| Not Used |
|
|
|
|
| CH3 | CH2 | CH1 | CH0 | |
Read |
|
|
|
|
| Not Used |
|
|
|
|
| CH3 | CH2 | CH1 | CH0 |
CH0 – CH3 Channel (1 = channel open
Reg. |
|
|
|
|
|
| ID EEPROM |
|
|
|
|
|
| |||
FE |
|
|
|
|
|
|
|
|
|
|
|
| ||||
Bit | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
Write |
|
|
|
|
|
| Unused |
|
|
|
|
|
| CS | CLK | I/O |
Read | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | I/O |
I/O Data In/Out (value from the Data Out pin of the ID EEPROM)
CLK Clock (1 = forces the SK pin of the ID EEPROM high, 0 = low)
CS Chip Select (1 = selects the ID EEPROM, 0 = deselects the ID EEPROM)
Notes:
1.The ID EEPROM register allows you to access the contents of the ID EEPROM which contains
2.CAUTION: Do not attempt to write to Bit00 of the ID EEPROM register. You could overwrite the contents of the EEPROM.
Figure 3. I/O Registers