Running in DMX Mode
This DMX mode enables the use of a universal DMX controller device. Each fixture requires a "start address" that can be set from 001 to 512. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address. For example, a fixture that occupies or uses 6 channels of DMX and was addressed to start on DMX channel 100, would read data from channels: 100, 101, 102, 103, 104, and 105. Choose start addresses so that the channels used do not overlap and notate the start address selected for future reference.
If this is your first time addressing a fixture using the
SELECT DMX MODE & SET ST ART ING ADDRESS
1)Press the MODE button until the display reads {Annn}, where n represents a number between 001 and 512.
2)Press the ( Button) and ( Button) to increase or decrease values until the desired DMX starting address is achieved.
OPT IONAL DIMMER/RELAY SETT ING
1)Press the MODE button until the display reads {Annn}, where n represents a number between 001 and 512.
2)Press the MENU button until the display reads
3)Press the ( Button) and ( Button) to toggle between
DMX CONT ROL CHANNEL MODES
1)Press the MODE button until the display reads {Annn}, where n represents a number between
001and 512.
2)Press the MENU button until the display reads {CH:nn}, where n represents a number between
01and 04.
3)Press the ( Button) and ( Button) to increase or decrease values to select a desired channel output
SELECTION | BEHAVIOR |
CH:01 | DMX channel 1 will control outputs (1 through 4 combined) |
CH:02 | DMX channel 1 will control outputs (1 and 2 combined) |
| DMX channel 2 will control outputs (3 and 4 combined) |
CH:04 | DMX channels 1 through 4 will control outputs 1 through 4 respectively |
Replacing a fuse
Disconnect the power cord before replacing a fuse and always
replace with the same type fuse.
With a Philips head screwdriver unscrew the fuse holder until it can be entirely removed. Remove the damaged fuse from its holder and replace with exact same type fuse. Insert the fuse holder back in its place and reconnect power.
FUSES: F10A 125V 5 X20mm
1 | 2 | 3 | 4 |