Delta Electronics DNL Series manual For DNM04xx and DNL04xx series, Vtrim = 0.7 − 0.1698 ⋅ Vout

Page 9

Table 2.

Vo,set

Rset (k ) R33

Recommend Value, R//R

0.7525

Open

Open

1.2

22.464

23.7k//432k

1.5

13.047

14.0k//191k

1.8

9.024

9.53k//169k

2.5

5.009

5.23k//118k

3.3

3.122

3.16k//261k

5.0

1.472

1.5k//78.7k

Test

1.Put the resistor to program the desired output voltage set point by follow Table 1 and Table 2 for the standard output.

2.Set the input voltage to the desired operating level while monitoring DVM2.

3.Turn on the fan.

4.Set the enable switch SW2 to the “ON” position to enable the converter.

5.Adjust the output load across the converter’s operating load range.

6.Note the output voltage over the full range of the operating load range (please refer to the data sheet for the detailed specification).

(2)Output Voltage Set-Point Adjustment by external voltage source

For DNM and DNL series, trim to Vo,set using an external voltage source, connect it between the TRIM pin and GND pin. Please refer to the Table 3 and Table 4 as below for the appropriate Vout. The value of Vtrim is specified as follows:

For DNM04xx and DNL04xx series

Vtrim = 0.7 − 0.1698 ⋅ (Vout − 0.7525)

For example, to program the output voltage of a DNL04S module to 3.3 Vdc, Vtrim is

calculated as follows:

 

 

 

Vtrim = 0.7 − 0.1698 ⋅ (3.3 − 0.7525) = 0.267V

 

 

Table 3. : Vo,set adjustment range using external voltage source.

 

 

Normal

 

 

 

Product Part

Output Set

Vrim (V)

 

 

Voltage

 

 

 

 

 

 

 

(Vdc)

 

 

 

 

0.7525

Open

 

 

DNM04S0A0S10P A/B/C

1.2

0.6240

 

 

DNM04S0A0S10N A/B/C

 

 

 

 

1.5

0.5730

 

 

DNL04S0A0S16P A/B/C

 

 

1.8

0.5220

 

 

DNL04S0A0S16N A/B/C

 

 

 

2.5

0.4030

 

 

 

 

 

 

 

 

3.3

0.2670

 

9

Image 9
Contents Delphi DNM and DNL Series of SMT type POL converters PurposeRelevant Documentation Equipment Set-Up and Description Equipment RequiredThermal Management of the Converter Test Set-Up Tests PerformedSW3 Function table Initial Power UpTests and Evaluation TestNo Load Input Current Test Output Characteristics Line Regulation Load RegulationOutput Ripple 10500 Vtrim = 0.7 − 0.1698 ⋅ Vout − For DNM04xx and DNL04xx seriesVoltage Margining For DNM12xx and DNL12xx seriesDetailed Description Sequential Implementation Voltage TrackingRatio-Metric Implementation PS1 PS2PS1=5V VrefSimultaneous Implementation PS1=5V PS2=3.3VVref define Test Dynamic Characteristics Output Voltage DeviationTest Turn on the module by using the external switch Test Turn on the module by using the Enable on/offTurn-On Response Time Thermal Characteristic Efficiency Appendix A- Evaluation Board Schematic Warranty