Delta Electronics LCP-2125 specifications Eeprom Serial ID Memory Contents 2-Wire Address A0h

Page 10

EEPROM Serial ID Memory Contents (2-Wire Address A0h)

Address

Hex

ASCII

Address

Hex

ASCII

Address

Hex

ASCII

00

03

 

43

PN

 

86

DC

 

01

04

 

44

PN

 

87

DC

 

02

07

 

45

PN

 

88

DC

 

03

00

Note 1

46

PN

 

89

DC

 

04

00

 

47

PN

 

90

DC

 

05

00

 

48

PN

 

91

DC

 

06

xx

 

49

PN

 

92

68

 

07

xx

 

50

PN

 

93

B0

 

08

xx

 

51

PN

 

94

02

 

09

xx

 

52

PN

 

95

CS2

Note 9

10

xx

 

53

PN

 

96

00

 

11

01

 

54

PN

 

97

00

 

12

15

 

55

PN

 

98

00

 

13

00

 

56

30

 

99

00

 

14

00

 

57

30

 

100

00

 

15

00

 

58

30

 

101

00

 

16

xx

Note 2

59

0A

 

102

00

 

17

xx

Note 3

60

CW

Note 5

103

00

 

18

00

 

61

CW

Note 5

104

00

 

19

00

 

62

00

 

105

00

 

20

44

D

63

CS1

Note 6

106

00

 

21

45

E

64

00

 

107

00

 

22

4C

L

65

1A

 

108

00

 

23

54

T

66

05

 

109

00

 

24

41

A

67

05

 

110

00

 

25

20

 

68

SN

Note 7

111

00

 

26

20

 

69

SN

 

112

00

 

27

20

 

70

SN

 

113

00

 

28

20

 

71

SN

 

114

00

 

29

20

 

72

SN

 

115

00

 

30

20

 

73

SN

 

116

00

 

31

20

 

74

SN

 

117

00

 

32

20

 

75

SN

 

118

00

 

33

20

 

76

SN

 

119

00

 

34

20

 

77

SN

 

120

00

 

35

20

 

78

SN

 

121

00

 

36

00

 

79

SN

 

122

00

 

37

00

 

80

SN

 

123

00

 

38

00

 

81

SN

 

124

00

 

39

00

 

82

SN

 

125

00

 

40

PN

Note4

83

SN

 

126

00

 

41

PN

 

84

DC

Note 8

127

00

 

42

PN

 

85

DC

 

128

00

Note 10

Notes:

 

 

 

 

 

 

 

 

1) Byte 3~10: Code for electronic compatibility or optical compatibility.

 

 

 

2) Byte 16: Link length supported for 50/125μm MM fiber, units of 10 m.

 

 

 

3) Byte 17: Link length supported for 62.5/125μm MM fiber, units of 10 m.

 

 

4) Byte 40-55: Delta part number

 

 

 

 

 

 

5) Byte 60-61: The center wavelength of transmitter

 

 

 

 

6) Byte 63: Check sum of bytes 0-62

 

 

 

 

 

7) Byte 68-83: Serial number

 

 

 

 

 

 

 

 

 

 

10

 

 

 

Nov., 2006

 

 

 

 

 

 

 

 

Rev. 1D

DELTA ELECTRONICS, INC.

 

 

 

www.deltaww.com

Image 10
Contents Applications Duplex LC Connector interfaceDescription PerformanceAbsolute Maximum Ratings Electrical CharacteristicsRecommended Operating Conditions Optical Characteristics Mask of the eye diagram for the optical transmit signalLOS Open PLD / PAL Package Outline Drawing Parameter Symbol Min Max Unit SFP timing parameters for SFP managementEnhanced Digital Diagnostic Interface Eeprom Serial ID Memory Contents 2-Wire Address A0h Address Name Digital Diagnostic Monitoring InterfaceUnit Bytes Optional Set of Alarm and Warning State/ Control BitsRegulatory Compliance EMC CisprOrdering information for SFP modules Function

LCP-2125 specifications

Delta Electronics is a global leader in power and thermal management solutions, and one of their renowned products is the LCP-2125, a cutting-edge liquid cooling pump designed for enhancing thermal management in various applications. The LCP-2125 is specifically engineered to cater to the demands of high-performance computing environments, data centers, and industrial processes that require efficient cooling solutions.

One of the standout features of the LCP-2125 is its high efficiency. Designed to minimize energy consumption while maximizing cooling performance, this pump employs advanced motor technology, reducing operational costs significantly. This is particularly beneficial in data centers, where cooling can account for a substantial portion of energy expenditure.

The LCP-2125 operates with a variable speed control mechanism, allowing for precise management of cooling power based on the specific temperature requirements of the system. This adaptability not only enhances energy efficiency but also prolongs the lifespan of equipment by ensuring they operate within optimal thermal conditions.

Another key characteristic of the LCP-2125 is its robust design, which is built to withstand harsh operational environments. The pump features corrosion-resistant materials and a durable casing that further protects against wear and tear, ensuring reliable performance over extended periods.

Delta Electronics integrates advanced monitoring and control technologies into the LCP-2125 as well. This includes real-time data tracking of flow rate, temperature, and pressure, allowing for proactive maintenance and quick identification of any potential issues. This level of monitoring is crucial in mission-critical settings where unplanned downtime can lead to significant repercussions.

Moreover, the LCP-2125 is designed for easy installation and maintenance, making it a convenient choice for facilities managers. Its compact size facilitates integration into various systems without occupying excessive space, which is an advantage in densely packed environments.

In conclusion, the Delta Electronics LCP-2125 liquid cooling pump stands out as a reliable solution that addresses the thermal management challenges of modern applications. With its energy-efficient design, robust construction, and advanced monitoring capabilities, it provides a perfect balance between performance, durability, and ease of use, making it an invaluable asset for industries reliant on high-performance computing and effective cooling systems.