Delta Electronics LCP-2125 specifications State/ Control Bits, Optional Set of Alarm and Warning

Page 12

PS: Sensitivity optical power of receiver

5)Byte 95 contains the low order 8bits of sum of bytes 0-94

State/ Control Bits

Byte

Bit

Name

Description

110

7

Tx Disable State

Digital state of the Tx disable input pin

110

6

Soft Tx Disable

Read/ Write bit that allow software disable of laser

110

5

Reserved

 

110

4

Rate Select tate

NA

110

3

Soft Rate Select

NA

110

2

Tx Fault

Digital state of the Tx fault output pin

110

1

LOS

Digital state of the LOS output pin.

110

0

Data_Ready_Bar

NA

7)

Optional Set of Alarm and Warning

Byte

Bit

Name

Description

112

7

Temp High Alarm

Set when internal temperature exceeds high alarm level

112

6

Temp Low Alarm

Set when internal temperature is below low alarm level

112

5

Vcc High Alarm

Set when internal supply voltage exceeds high alarm level

112

4

Vcc Low Alarm

Set when internal supply voltage is below low alarm level

112

3

Tx Bias High Alarm

Set when Tx Bias current exceeds high alarm level

112

2

Tx Bias Low Alarm

Set when Tx Bias current is below low alarm level

112

1

Tx Power High Alarm

Set when Tx output power exceeds high alarm level

112

0

Tx Power Low Alarm

Set when Tx output power is below low alarm level

113

7

Rx Power High Alarm

Set when received power exceeds high alarm level

113

6

Rx Power Low Alarm

Set when received power is below low alarm level

113

5-0

Reserved

 

116

7

Temp High Warning

Set when internal temperature exceeds high warning level

116

6

Temp Low Warning

Set when internal temperature is below low warning level

116

5

Vcc High Warning

Set when internal supply voltage exceeds high warning level

116

4

Vcc Low Warning

Set when internal supply voltage is below low warning level

116

3

Tx Bias High Warning

Set when Tx Bias current exceeds high warning level

116

2

Tx Bias Low Warning

Set when Tx Bias current is below low warning level

116

1

Tx Power High Warning

Set when Tx output power exceeds high warning level

116

0

Tx Power Low Warning

Set when Tx output power is below low warning level

117

7

Rx Power High Warning

Set when received power exceeds high warning level

117

6

Rx Power Low Warning

Set when received power is below low warning level

117

5-0

Reserved

 

Digital Diagnostic Monitor Accuracy

 

Parameter

Typical Value

Note

 

 

 

 

 

 

 

Transceiver Temperature

± 3

1

 

 

Power Supply Voltage

± 3%

2

 

 

TX Bias Current

± 10%

 

 

 

TX Optical Power

± 1.5dB

 

 

 

RX Optical Power

± 3dB

 

 

Notes:

 

 

 

 

 

12

Nov., 2006

 

 

 

Rev. 1D

DELTA ELECTRONICS, INC.

 

www.deltaww.com

Image 12
Contents Duplex LC Connector interface DescriptionApplications PerformanceElectrical Characteristics Absolute Maximum RatingsRecommended Operating Conditions Optical Characteristics Mask of the eye diagram for the optical transmit signalLOS Open PLD / PAL Package Outline Drawing Parameter Symbol Min Max Unit SFP timing parameters for SFP managementEnhanced Digital Diagnostic Interface Eeprom Serial ID Memory Contents 2-Wire Address A0h Digital Diagnostic Monitoring Interface Address NameUnit Bytes Optional Set of Alarm and Warning State/ Control BitsRegulatory Compliance EMC CisprOrdering information for SFP modules Function

LCP-2125 specifications

Delta Electronics is a global leader in power and thermal management solutions, and one of their renowned products is the LCP-2125, a cutting-edge liquid cooling pump designed for enhancing thermal management in various applications. The LCP-2125 is specifically engineered to cater to the demands of high-performance computing environments, data centers, and industrial processes that require efficient cooling solutions.

One of the standout features of the LCP-2125 is its high efficiency. Designed to minimize energy consumption while maximizing cooling performance, this pump employs advanced motor technology, reducing operational costs significantly. This is particularly beneficial in data centers, where cooling can account for a substantial portion of energy expenditure.

The LCP-2125 operates with a variable speed control mechanism, allowing for precise management of cooling power based on the specific temperature requirements of the system. This adaptability not only enhances energy efficiency but also prolongs the lifespan of equipment by ensuring they operate within optimal thermal conditions.

Another key characteristic of the LCP-2125 is its robust design, which is built to withstand harsh operational environments. The pump features corrosion-resistant materials and a durable casing that further protects against wear and tear, ensuring reliable performance over extended periods.

Delta Electronics integrates advanced monitoring and control technologies into the LCP-2125 as well. This includes real-time data tracking of flow rate, temperature, and pressure, allowing for proactive maintenance and quick identification of any potential issues. This level of monitoring is crucial in mission-critical settings where unplanned downtime can lead to significant repercussions.

Moreover, the LCP-2125 is designed for easy installation and maintenance, making it a convenient choice for facilities managers. Its compact size facilitates integration into various systems without occupying excessive space, which is an advantage in densely packed environments.

In conclusion, the Delta Electronics LCP-2125 liquid cooling pump stands out as a reliable solution that addresses the thermal management challenges of modern applications. With its energy-efficient design, robust construction, and advanced monitoring capabilities, it provides a perfect balance between performance, durability, and ease of use, making it an invaluable asset for industries reliant on high-performance computing and effective cooling systems.