SFP timing parameters for SFP management
| 
 | Parameter | 
 | Symbol | Min. | Max. | 
 | Unit | Note | |
| 
 | TX_DISABLE Assert time | 
 | t_off | 
 | 10 | 
 | μsec | 1 | 
 | 
| 
 | TX_DISABLE Negate time | 
 | t_on | 
 | 1 | 
 | msec | 2 | 
 | 
| 
 | Time to initialize, including | 
 | t_init | 
 | 300 | 
 | msec | 3 | 
 | 
| 
 | reset of TX_FAULT | 
 | 
 | 
 | 
 | ||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | TX Fault Assert Time | 
 | t_fault | 
 | 100 | 
 | μsec | 4 | 
 | 
| 
 | TX_DISABLE to reset | 
 | t_rest | 10 | 
 | 
 | μsec | 5 | 
 | 
| 
 | LOS Assert Time | 
 | t_loss_on | 
 | 100 | 
 | μsec | 6 | 
 | 
| 
 | LOS Deassert Time | 
 | t_loss_off | 
 | 100 | 
 | μsec | 7 | 
 | 
| 
 | Serial ID Clock Rate | 
 | f_serial_clock | 
 | 100 | 
 | kHz | 
 | 
 | 
Notes:
1)Time from rising edge of TX_DISABLE to when the optical output falls below 10% of nominal
2)Time from falling edge of TX_DISABLE to when the modulated optical output rises above 90% of nominal
3)From power on or negation of TX_Fault using TX Disable
4)Time from fault to TX fault on.
5)Time TX Disable must be held high to reset TX_Fault
6)Time from LOS state to Rx LOS assert
7)Time from 
| 7 | 2008/3/14 | 
| 
 | Rev. 0B | 
| DELTA ELECTRONICS, INC. | www.deltaww.com |