SFP timing parameters for SFP management
| Parameter |
| Symbol | Min. | Max. |
| Unit | Note | |
| TX_DISABLE Assert time |
| t_off |
| 10 |
| μsec | 1 |
|
| TX_DISABLE Negate time |
| t_on |
| 1 |
| msec | 2 |
|
| Time to initialize, including |
| t_init |
| 300 |
| msec | 3 |
|
| reset of TX_FAULT |
|
|
|
| ||||
|
|
|
|
|
|
|
|
| |
| TX Fault Assert Time |
| t_fault |
| 100 |
| μsec | 4 |
|
| TX_DISABLE to reset |
| t_rest | 10 |
|
| μsec | 5 |
|
| LOS Assert Time |
| t_loss_on |
| 100 |
| μsec | 6 |
|
| LOS Deassert Time |
| t_loss_off |
| 100 |
| μsec | 7 |
|
| Serial ID Clock Rate |
| f_serial_clock |
| 100 |
| kHz |
|
|
Notes:
1)Time from rising edge of TX_DISABLE to when the optical output falls below 10% of nominal
2)Time from falling edge of TX_DISABLE to when the modulated optical output rises above 90% of nominal
3)From power on or negation of TX_Fault using TX Disable
4)Time from fault to TX fault on.
5)Time TX Disable must be held high to reset TX_Fault
6)Time from LOS state to Rx LOS assert
7)Time from
7 | 2008/3/14 |
| Rev. 0B |
DELTA ELECTRONICS, INC. | www.deltaww.com |