Delta Electronics LCP-2488B4HDRx manual SFP timing parameters for SFP management

Page 7

SFP timing parameters for SFP management

 

Parameter

 

Symbol

Min.

Max.

 

Unit

Note

 

TX_DISABLE Assert time

 

t_off

 

10

 

μsec

1

 

 

TX_DISABLE Negate time

 

t_on

 

1

 

msec

2

 

 

Time to initialize, including

 

t_init

 

300

 

msec

3

 

 

reset of TX_FAULT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TX Fault Assert Time

 

t_fault

 

100

 

μsec

4

 

 

TX_DISABLE to reset

 

t_rest

10

 

 

μsec

5

 

 

LOS Assert Time

 

t_loss_on

 

100

 

μsec

6

 

 

LOS Deassert Time

 

t_loss_off

 

100

 

μsec

7

 

 

Serial ID Clock Rate

 

f_serial_clock

 

100

 

kHz

 

 

Notes:

1)Time from rising edge of TX_DISABLE to when the optical output falls below 10% of nominal

2)Time from falling edge of TX_DISABLE to when the modulated optical output rises above 90% of nominal

3)From power on or negation of TX_Fault using TX Disable

4)Time from fault to TX fault on.

5)Time TX Disable must be held high to reset TX_Fault

6)Time from LOS state to Rx LOS assert

7)Time from non-LOS state to Rx LOS deassert

7

2008/3/14

 

Rev. 0B

DELTA ELECTRONICS, INC.

www.deltaww.com

Image 7
Contents Description Duplex LC Connector interfacePerformance Absolute Maximum Ratings Electrical CharacteristicsRecommended Operating Conditions Mask of the eye diagram for the optical transmit signal Optical CharacteristicsMOD-DEF2 Open PLD / PAL SFP timing parameters for SFP management Parameter Symbol Min Max UnitPackage Outline Drawing Enhanced Digital Diagnostic Interface Eeprom Serial ID Memory Contents 2-Wire Address A0h Address Name Value Dec Unit Bytes Digital Diagnostic Monitoring InterfaceState/ Control Bits Optional Set of Alarm and WarningRegulatory Compliance X1 TemperatureOrdering information for SFP modules