Delta Electronics LCP-2488B4HDRx manual Digital Diagnostic Monitoring Interface

Page 11

Digital Diagnostic Monitoring Interface

Alarm and Warning Thresholds (2-Wire Address A2h)

 

 

Address

 

#

 

Name

 

Value (Dec.)

 

Unit

 

 

Note

 

 

 

 

Bytes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00-01

2

 

Temp High Alarm

TC (MAX.)+8

1

 

02-03

2

 

Temp Low Alarm

TC (MIN.)-8

 

 

 

 

 

04-05

2

 

Temp High Warning

TC (MAX.)+3

 

 

 

 

 

06-07

2

 

Temp Low Warning

TC (MIN.)-3

 

 

 

 

 

08-09

2

 

Voltage High Alarm

Vcc+0.5

Volt

 

 

 

 

 

10-11

2

 

Voltage Low Alarm

Vcc-0.5

 

 

 

 

 

 

12-13

 

2

 

Voltage High Warning

Vcc+0.2

 

 

 

 

 

 

14-15

 

2

 

Voltage Low Warning

 

Vcc-0.2

 

 

 

 

 

16-17

2

 

Bias High Alarm

IOP*2+20

mA

2

 

18-19

2

Bias Low Alarm

IOP-20

 

 

 

 

 

20-21

2

 

Bias High Warning

IOP *2+10

 

 

 

 

 

22-23

2

 

Bias Low Warning

IOP -10

 

 

 

 

 

24-25

2

 

TX Power High Alarm

Ph+2

dBm

 

 

3

 

 

26-27

2

 

TX Power Low Alarm

Pl -2

 

 

 

 

 

 

28-29

 

2

 

TX Power High Warning

Ph+1

 

 

 

 

 

 

30-31

 

2

 

TX Power Low Warning

 

Pl -1

 

 

 

 

 

32-33

2

 

RX Power High Alarm

P0+2

dBm

4

 

34-35

2

 

RX Power Low Alarm

PS-2

 

 

 

 

 

36-37

2

 

RX Power High Warning

P0+1

 

 

 

 

 

38-39

2

 

RX Power Low Warning

PS-1

 

 

 

 

 

40-45

16

 

Reversed

 

 

 

 

 

 

 

56-91

36

 

External Calibration Constants

 

 

 

 

 

 

 

92-94

3

 

Reversed

 

 

 

 

 

 

 

95

1

 

Checksum

 

 

 

 

 

5

 

96-97

2

Real Time Temperature

 

 

 

 

 

 

 

98-99

2

Real Time Supply Voltage

 

 

 

 

 

 

 

100-101

2

Real Time Tx Bias Current

 

 

 

 

 

 

 

102-103

2

Real Time Tx Optical Power

 

 

 

 

 

 

 

104-105

2

Real Time Rx Received Power

 

 

 

 

 

 

 

106-109

4

 

Reserved

 

 

 

 

 

 

 

110

1

 

Optional Status/ Control Bits

 

 

 

 

 

6

 

111

1

 

Reserved

 

 

 

 

 

 

 

112-119

8

 

Optional Set of Alarm and Warning

 

 

 

 

 

7

 

Notes:

1)TC: Case Operating temperature

2)IOP: Operating current at room temperature. The min. setting current is 0 mA.

3)Ph: Maximum value of transmitter optical power

 

Pl: Minimum value of transmitter optical power

 

4)

P0: Overload optical power of receiver

 

 

PS: Sensitivity optical power of receiver

 

5)

Byte 95 contains the low order 8bits of sum of bytes 0-94

 

 

11

2008/3/14

 

 

Rev. 0B

DELTA ELECTRONICS, INC.

www.deltaww.com

Image 11
Contents Performance Duplex LC Connector interfaceDescription Recommended Operating Conditions Electrical CharacteristicsAbsolute Maximum Ratings Mask of the eye diagram for the optical transmit signal Optical CharacteristicsMOD-DEF2 Open PLD / PAL SFP timing parameters for SFP management Parameter Symbol Min Max UnitPackage Outline Drawing Enhanced Digital Diagnostic Interface Eeprom Serial ID Memory Contents 2-Wire Address A0h Address Name Value Dec Unit Bytes Digital Diagnostic Monitoring InterfaceState/ Control Bits Optional Set of Alarm and WarningOrdering information for SFP modules X1 TemperatureRegulatory Compliance