Delta Electronics LCP-4250A4CDR manual Regulatory Compliance, Ordering information for SFP modules

Page 13

Regulatory Compliance

Test Item

Reference

Qty’

Evaluation

 

 

 

 

(#1)

FCC Class B

 

 

Electromagnetic Interference

EN 55022 Class B

5

 

EMC

CISPR 22

 

 

 

 

 

 

(#2) Immunity

EN 61000-4-3

 

 

 

5

 

Radio Frequency

IEC 1000-4-3

 

 

 

Electromagnetic Field

 

(1) Satisfied with electrical characteristics of

 

 

 

 

 

 

 

 

product spec.

(#3) Immunity

EN 61000-4-2

 

 

 

Electrostatic Discharge to the

IEC 1000-4-2

5

 

Duplex SC Receptacle

IEC 801.2

 

(2) No physical damage

 

 

 

 

 

 

 

(#4) Electrostatic Discharge to

MIL-STD-883C

 

 

the Electrical Pins

Method 3015.4

 

 

 

EIAJ#1988.3.2B

5

 

 

 

 

 

Version 2,

 

 

 

Machine model

 

 

 

 

 

 

Ordering information for SFP modules

LCP-4250A4CDRX1

X1: Temperature

Blank: -5 to +70 degree C

H: -10 to +85 degree C

T: -40 to +85 degree C

13

2008/3/18

 

Rev. 0A

DELTA ELECTRONICS, INC.

www.deltaww.com

Image 13
Contents Applications DescriptionTransmission Distances Absolute Maximum Ratings Electrical CharacteristicsRecommended Operating Conditions Optical Characteristics Mask of the eye diagram for the optical transmit signalMOD-DEF2 Open SerDes IC Recommend Circuit SchematicPackage Outline Drawing for Metal Housing with Bail de-latch SFP timing parameters for SFP management Parameter Symbol Min Max UnitEnhanced Digital Diagnostic Interface Eeprom Serial ID Memory Contents 2-Wire Address A0h Alarm and Warning Thresholds 2-Wire Address A2h Digital Diagnostic Monitoring InterfaceAddress Name Value Dec Unit Bytes Optional Set of Alarm and Warning Digital Diagnostic Monitor Accuracy Parameter Typical ValueState/ Control Bits Regulatory Compliance X1 TemperatureOrdering information for SFP modules