SFP timing parameters for SFP management
  | Parameter | 
  | Symbol | Min. | 
  | Max. | 
  | Unit | 
  | Note  | 
  | 
  | TX_DISABLE Assert time  | t_off  | 
  | 10  | 
  | µsec  | 1  | 
  | |||
  | TX_DISABLE Negate time  | 
  | t_on  | 
  | 
  | 1  | 
  | msec  | 
  | 2  | 
  | 
  | Time to initialize, including  | t_init  | 
  | 300  | 
  | msec  | 3  | 
  | |||
  | reset of TX_FAULT  | 
  | 
  | 
  | |||||||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | ||
  | TX Fault Assert Time  | 
  | t_fault  | 
  | 
  | 100  | 
  | µsec  | 
  | 4  | 
  | 
  | TX_DISABLE to reset  | t_rest  | 10  | 
  | 
  | 
  | µsec  | 5  | 
  | ||
  | LOS Assert Time  | 
  | t_loss_on  | 
  | 
  | 100  | 
  | µsec  | 
  | 6  | 
  | 
  | LOS Deassert Time  | t_loss_off  | 
  | 100  | 
  | µsec  | 7  | 
  | |||
  | Serial ID Clock Rate  | 
  | f_serial_clock  | 
  | 
  | 100  | 
  | kHz  | 
  | 
  | 
  | 
Notes:
1)Time from rising edge of TX_DISABLE to when the optical output falls below 10% of nominal.
2)Time from falling edge of TX_DISABLE to when the modulated optical output rises above 90% of nominal.
3)From power on or negation of TX_Fault using TX Disable.
4)Time from fault to TX fault on.
5)Time TX Disable must be held high to reset TX_Fault.
6)Time from LOS state to Rx LOS assert.
7)Time from 
8  | 2008/3/18  | 
  | Rev. 0A  | 