Delta Electronics LCP-4250A4CDR manual Enhanced Digital Diagnostic Interface

Page 9

Enhanced Digital Diagnostic Interface

The memory map in the following describes an extension to the memory map defined in SFP MSA. The enhanced

interface uses the two wire serial bus address 1010001X(A2h) to provide diagnostic information about the module’s

present operating conditions.

0

95

96

127

128

255

2 wire address 1010000 X (A0h)

Serial ID Defined by SFP MSA (96 bytes)

Vender Specific (32 bytes)

Reserved in SFP MSA (128 bytes)

0

55

56

95

96

119

120

127

128

247

248

255

2 wire address 1010001 X (A2h)

Alarm and Warning Thresholds

(56 bytes)

Cal Constants

(40 bytes)

Real Time Diagnostic Interface (24 bytes)

Vender Specific(Note)

User Writable EEPROM

(120 bytes)

Vender Specific

(8 bytes)

Note:

Digital Diagnostic Memory Map Specific Data Field Descriptions

1)Write the password (11h, 11h, 11h, 11h) on the bytes of 123-126 of address A2h then the address of bytes 128-255 (User Writable) can be read and written.

9

2008/3/18

 

Rev. 0A

DELTA ELECTRONICS, INC.

www.deltaww.com

Image 9
Contents Description ApplicationsTransmission Distances Electrical Characteristics Absolute Maximum RatingsRecommended Operating Conditions Optical Characteristics Mask of the eye diagram for the optical transmit signalMOD-DEF2 Open SerDes IC Recommend Circuit SchematicPackage Outline Drawing for Metal Housing with Bail de-latch SFP timing parameters for SFP management Parameter Symbol Min Max UnitEnhanced Digital Diagnostic Interface Eeprom Serial ID Memory Contents 2-Wire Address A0h Digital Diagnostic Monitoring Interface Alarm and Warning Thresholds 2-Wire Address A2hAddress Name Value Dec Unit Bytes Digital Diagnostic Monitor Accuracy Parameter Typical Value Optional Set of Alarm and WarningState/ Control Bits X1 Temperature Regulatory ComplianceOrdering information for SFP modules