Delta Electronics LCP-10G3B4QDR manual Eeprom Serial ID Memory Contents 2-Wire Address A0h

Page 11

LCP-10G3B4QDR

EEPROM Serial ID Memory Contents (2-Wire Address A0h)

Address

Hex

ASCII

Address

 

Hex

 

ASCII

 

Address

 

Hex

ASCII

00

03

 

43

 

2D

-

86

 

DC

 

01

04

 

44

31

1

87

 

DC

 

02

07

 

45

30

0

88

 

DC

 

03

20

10G Base-LR

46

47

 

G

89

 

DC

 

04

00

 

47

 

33

 

3

 

90

 

DC

 

05

00

 

48

 

42

 

B

 

91

 

DC

 

06

00

 

49

 

34

 

4

 

92

 

68

 

07

00

 

50

 

51

 

Q

 

93

 

F0

 

08

00

 

51

 

44

 

D

 

94

 

03

 

09

00

 

52

52

 

R

95

 

CS2

Note 4

10

00

 

53

20

 

 

96

00

 

11

03

 

54

20

 

 

97

00

 

12

67

 

55

 

20

 

 

 

98

 

00

 

13

00

 

56

 

41

 

 

 

99

 

00

 

14

0A

10km

57

 

20

 

 

 

100

 

00

 

15

64

10km

58

 

20

 

 

 

101

 

00

 

16

00

 

59

 

20

 

 

 

102

 

00

 

17

00

 

60

05

 

1310nm

103

00

 

18

00

 

61

 

1E

 

1310nm

104

00

 

19

00

 

62

00

 

 

105

00

 

20

44

D

63

 

CS1

 

Note 1

 

106

 

00

 

21

45

E

64

 

01

 

 

 

107

 

00

 

22

4C

L

65

 

1A

 

 

 

108

 

00

 

23

54

T

66

 

00

 

 

 

109

 

00

 

24

41

A

67

 

00

 

 

 

110

 

00

 

25

20

 

68

 

SN

 

Note 2

111

00

 

26

20

 

69

 

SN

 

 

112

00

 

27

20

 

70

 

SN

 

 

113

00

 

28

20

 

71

 

SN

 

 

 

114

 

00

 

29

20

 

72

 

SN

 

 

 

115

 

00

 

30

20

 

73

 

SN

 

 

 

116

 

00

 

31

20

 

74

 

SN

 

 

 

117

 

00

 

32

20

 

75

 

SN

 

 

 

118

 

00

 

33

20

 

76

 

SN

 

 

119

00

 

34

20

 

77

 

SN

 

 

120

00

 

35

20

 

78

 

SN

 

 

121

00

 

36

00

 

79

 

SN

 

 

 

122

 

00

 

37

00

 

80

 

SN

 

 

 

123

 

00

 

38

00

 

81

 

SN

 

 

 

124

 

00

 

39

00

 

82

 

SN

 

 

 

125

 

00

 

40

4C

L

83

 

SN

 

 

 

126

 

00

 

41

43

C

84

 

DC

 

Note 3

127

00

 

42

50

P

85

 

DC

 

 

128

00

Note 5

Notes:

1)Byte 63: Check sum of bytes 0-62.

2)Byte 68-83: Serial number.

3)Byte 84-91: Date code.

4)Byte 95: Check sum of bytes 64-94.

5)Byte 128 to 255 had been set hex 00.

11

Revision: 0B

 

2008/9/5

DELTA ELECTRONICS, INC.

www.deltaww.com

Image 11
Contents Performance DescriptionApplications Recommended Operating Conditions Low Speed Electrical CharacteristicsAbsolute Maximum Ratings Parameter Symbol Min Typ Max Units Optical Transmitter Characteristics TC = -5toOptical Receive Characteristics TC=0 ºC to 70 ºC Parameter Symbol Min Typ UnitsSFP+ Transceiver Electrical Pad Layout Module Electrical Pin Definition Pin Logic Symbol Name/Description‧ Modabs ‧ Rxlos Low speed electrical control pins and 2-wire interfaceTXFault TXDisableRecommend Circuit Schematic Latch Color Identifier Package Outline Drawing for Metal Housing with Bail de-latchRS1FC Parameter Symbol Min Max UnitTiming parameters for SFP+ management TBDEnhanced Digital Diagnostic Interface Eeprom Serial ID Memory Contents 2-Wire Address A0h Address Name Value Dec Unit Bytes Digital Diagnostic Monitoring InterfaceState/ Control Bits Optional Set of Alarm and WarningRegulatory Compliance Feature Test Method Reference Performance

LCP-10G3B4QDR specifications

Delta Electronics has established itself as a leader in providing innovative power solutions, and one of their notable products is the LCP-10G3B4QDR, a high-performance rack-mounted Power Distribution Unit (PDU) that addresses the growing demands of data centers and IT infrastructure.

The LCP-10G3B4QDR is designed to offer efficient power management and distribution capabilities in a compact form factor. One of its standout features is the ability to support a wide range of input voltages, allowing it to be adaptable to various electrical environments and enhancing its compatibility with existing systems.

This PDU comes equipped with 10 outlets, ensuring ample power supply to critical equipment while also minimizing the footprint required for installation. The outlets are strategically placed to ensure easy access and efficient cable management, which is essential in densely packed data center environments.

A major characteristic of the LCP-10G3B4QDR is its integrated monitoring capabilities. The unit features real-time monitoring of power consumption and environmental conditions, including temperature and humidity. This functionality is crucial for data center managers, as it enables proactive management of power use and cooling requirements, leading to improved operational efficiencies and reduced energy costs.

The device supports advanced communication protocols, including SNMP, HTTP, and HTTPS, allowing seamless integration with existing network management systems. This connectivity is important for remote monitoring and management, enabling administrators to keep track of their power distribution from virtually anywhere.

Furthermore, Delta has incorporated cutting-edge safety features into the LCP-10G3B4QDR. The device complies with international safety standards, ensuring it meets rigorous testing requirements for reliable operation. Additionally, built-in surge protection safeguards sensitive equipment from power spikes, thereby enhancing overall reliability.

In terms of design, the LCP-10G3B4QDR features a space-saving, rack-mountable format that simplifies installation in standard 19-inch server racks. Its durable construction and cooling designs ensure that it can withstand the demanding conditions of a data center environment.

In conclusion, the Delta Electronics LCP-10G3B4QDR stands out with its robust feature set, focusing on flexibility, efficiency, and safety. As data centers continue to evolve, products like the LCP-10G3B4QDR become essential for ensuring that critical operations run smoothly and efficiently.