Delta Electronics VFD-XXXM quick start Description of Digital Keypad

Page 5

Description of Digital Keypad

The digital keypad includes two parts: Display panel and keypad. The display panel provides the parameter display and shows the operation status of the AC drive and the keypad provides programming and control interface.

 

 

 

 

 

 

 

DIGITAL KEYPAD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED Display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indicates motor and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Program/Function mode key

 

 

 

 

 

 

 

 

 

 

 

 

 

 

drive parameter.

Selects normal mode/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED Indicates

program mode. Displays

RUN STOP

FWD REV

 

 

Lamp lights during RUN,

the AC drive status, such as

 

 

STOP, FWD & REV

output freq., selects the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

operation.

parameters.

MODE

 

 

 

 

 

 

 

 

RUN

 

 

Run key

Enter Key

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Starts AC drive operation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press ENTER after

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STOP/RESET Key

 

 

 

 

 

 

 

 

 

 

STOP

key in the elected

ENTER

 

 

 

 

 

 

 

 

 

Stops and resets the

 

 

 

 

 

 

 

RESET

 

 

parameters or

 

 

 

 

 

 

 

 

 

 

 

 

parameter after a fault

change data.

50

 

 

 

 

 

 

 

 

 

 

 

 

 

occurs.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UP and DOWN Key

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Potentiometer

 

 

 

 

 

 

VFD-M

 

 

Sets the parameter number

For master Frequency

 

 

 

 

 

 

 

 

 

or changes the numerical

setting refer to Pr.00.

 

 

 

 

 

 

 

 

data such as the freq.

 

 

 

 

 

 

 

 

reference.

0 100

FREQ SET

LC-M02E

How to Operate the Digital Keypad LC-M02E

Selection mode

START

MODE

MODE

MODE

MODE

MODE

GO START

NOTE: In the selection mode, press ENTER to set the parameters.

To set parameters

ENTER

ENTER

ENTER

parameter set

successfully

or

or

MODE move to previous

displayparameter set error

NOTE: In the parameter setting mode, you can press MODE to return to the selection mode.

To modify data

START

To set direction

(When operation source is digital keypad)

or

or

English-5

Image 5
Contents Preface Voltage Class SpecificationsVoltage Class 575V Class L1 NFB Basic Wiring DiagramDescription of Digital Keypad How to Operate the Digital Keypad LC-M02EMax Wire Power TerminalsWire Type 75 oC Copper Only Model NameTerminal Symbol Explanation of Terminal Function Control Terminal Wiring Factory SettingTerminal Terminal Function Factory Settings NPN mode Terminal ExplanationsTerminal Summary of Parameter Settings Parameter Explanation Settings Factory Customer 01 M0 RUN/STOP, M1 REV/FWD Reset00 M0 FWD/STOP, M1 REV/STOP FLA English-13 CFA English-15 AC Drive Runs and Fan On, AC Drive English-17 English-18 Fault Codes OC hardware error External FaultOver-current DuringDimensions English-22

VFD-XXXM specifications

Delta Electronics VFD-XXXM series represents a cutting-edge advancement in variable frequency drive (VFD) technology, catering to a diverse range of industrial applications. Designed for efficiency, reliability, and ease of integration, the VFD-XXXM series is an ideal choice for motor control systems in various sectors, including manufacturing, HVAC, and water treatment.

One of the standout features of the VFD-XXXM is its precise motor control capability. The drive supports multiple control modes, including V/f control, Vector Control, and Sensorless Vector Control, allowing users to optimize performance based on application needs. This flexibility ensures smooth operation and improved energy efficiency, making it suitable for both simple and complex motor tasks.

In terms of design, the VFD-XXXM series is compact and user-friendly. With an intuitive keypad and clear display, operators can easily navigate and configure the settings. This ease of use significantly reduces setup time and enhances operational efficiency. Additionally, the unit’s robust construction allows it to perform reliably in harsh industrial environments, with features such as IP20/IP55 protection ratings, making it resistant to dust and moisture.

One of the key technologies embedded in the VFD-XXXM is the Advanced Energy Saving Algorithm, which continuously optimizes the energy consumption of the connected motor. This feature not only reduces operational costs but also contributes to environmental sustainability initiatives by minimizing power waste.

The series boasts an extensive array of communication options, including Modbus, CANopen, and Ethernet interfaces, enabling seamless integration with existing automation systems. This connectivity enhances flexibility and allows for real-time monitoring and control, improving overall system performance.

Moreover, the VFD-XXXM includes comprehensive built-in safety features, such as overload protection, short circuit protection, and a safe torque off function. These safety characteristics ensure the protection of both the drive and the motor, promoting a secure operational environment.

In conclusion, Delta Electronics VFD-XXXM series stands out due to its advanced features, robust design, and energy-efficient technologies. Its versatility makes it an exceptional choice for varied industrial applications, providing businesses with reliable and sustainable motor control solutions that enhance both performance and efficiency.