Delta Electronics VFD-XXXM quick start Terminal

Page 8

Terminal

Terminal Function

 

Factory Settings (NPN mode)

Symbol

 

 

 

 

 

 

 

M0 Multi-function auxiliary input

M0~M5-GND

 

M1 Multi-function input 1

 

 

 

Refer to P38~P42 for programming the multi-function

M2 Multi-function input 2

 

 

inputs.

 

M3 Multi-function input 3

 

 

 

ON: the activation current is 10 mA.

M4 Multi-function input 4

 

 

OFF: leakage current tolerance is 10μA.

M5 Multi-function input 5

 

 

 

 

GND

Common Signal

 

 

+10V-GND

 

+10V

+10 Vdc Output

 

 

 

 

 

It can supply +10 VDC power.

 

Analog Voltage Input

 

 

 

 

 

 

+10V

AVI

Circuit

 

 

 

 

 

 

 

 

AVI

 

 

 

 

Impedance: 20kΩ

 

AVI

 

 

 

Resolution: 10 bits

 

 

 

 

 

 

Range: 0~10Vdc = 0~Max.Output Frequency

 

ACM

Internal Circuit

 

 

 

 

 

 

 

 

 

Analog Current Input

 

 

 

 

ACI

ACI Circuit

 

 

 

ACI

 

 

 

 

Impedance: 250Ω

 

 

 

 

 

Resolution: 10 bits

 

 

 

 

 

 

Range: 4~20mA = 0~Max.Output Frequency

 

ACM

Internal Circuit

 

 

 

 

Analog Output Meter

 

 

 

 

ACM Circuit

AFM

 

 

 

 

 

 

 

 

0 to 10V, 2mA

 

 

 

 

 

 

 

AFM

 

 

0~10V Potentiometer

2mAMax.

Impedance: 100kΩ

 

 

Output Current: 2mA max

 

 

 

 

 

Resolution: 8 bits

 

 

 

 

 

 

Range: 0 ~ 10Vdc

 

 

Internal Circuit

ACM

 

Maximum: 48Vdc, 50mA

 

 

 

 

 

 

 

 

 

 

Refer to P45 for programming.

 

 

 

 

 

MO1-DCM

Max: 48Vdc/50mA

MO1

Multi-function Output Terminal

 

MO1

(Photocoupler)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Internal Circuit

MCM

MCM

Multi-function Output Common

Common for Multi-function Outputs

 

(Photocoupler)

 

 

 

 

Note: Use twisted-shielded, twisted-pair or shielded-lead wires for the control signal wiring. It is recommended to run all signal wiring in a separate steel conduit. The shield wire should only be connected at the drive. Do not connect shield wire on both ends.

English-8

Image 8
Contents Preface Specifications Voltage ClassVoltage Class 575V Class Basic Wiring Diagram L1 NFBHow to Operate the Digital Keypad LC-M02E Description of Digital KeypadPower Terminals Max WireWire Type 75 oC Copper Only Model NameControl Terminal Wiring Factory Setting Terminal Symbol Explanation of Terminal FunctionTerminal Terminal Function Factory Settings NPN mode Terminal ExplanationsTerminal Summary of Parameter Settings Parameter Explanation Settings Factory Customer 01 M0 RUN/STOP, M1 REV/FWD Reset00 M0 FWD/STOP, M1 REV/STOP FLA English-13 CFA English-15 AC Drive Runs and Fan On, AC Drive English-17 English-18 Fault Codes External Fault OC hardware errorOver-current DuringDimensions English-22

VFD-XXXM specifications

Delta Electronics VFD-XXXM series represents a cutting-edge advancement in variable frequency drive (VFD) technology, catering to a diverse range of industrial applications. Designed for efficiency, reliability, and ease of integration, the VFD-XXXM series is an ideal choice for motor control systems in various sectors, including manufacturing, HVAC, and water treatment.

One of the standout features of the VFD-XXXM is its precise motor control capability. The drive supports multiple control modes, including V/f control, Vector Control, and Sensorless Vector Control, allowing users to optimize performance based on application needs. This flexibility ensures smooth operation and improved energy efficiency, making it suitable for both simple and complex motor tasks.

In terms of design, the VFD-XXXM series is compact and user-friendly. With an intuitive keypad and clear display, operators can easily navigate and configure the settings. This ease of use significantly reduces setup time and enhances operational efficiency. Additionally, the unit’s robust construction allows it to perform reliably in harsh industrial environments, with features such as IP20/IP55 protection ratings, making it resistant to dust and moisture.

One of the key technologies embedded in the VFD-XXXM is the Advanced Energy Saving Algorithm, which continuously optimizes the energy consumption of the connected motor. This feature not only reduces operational costs but also contributes to environmental sustainability initiatives by minimizing power waste.

The series boasts an extensive array of communication options, including Modbus, CANopen, and Ethernet interfaces, enabling seamless integration with existing automation systems. This connectivity enhances flexibility and allows for real-time monitoring and control, improving overall system performance.

Moreover, the VFD-XXXM includes comprehensive built-in safety features, such as overload protection, short circuit protection, and a safe torque off function. These safety characteristics ensure the protection of both the drive and the motor, promoting a secure operational environment.

In conclusion, Delta Electronics VFD-XXXM series stands out due to its advanced features, robust design, and energy-efficient technologies. Its versatility makes it an exceptional choice for varied industrial applications, providing businesses with reliable and sustainable motor control solutions that enhance both performance and efficiency.