Installing the AlphaServer IP Platform Hardware

2.4.1.1.2 Connecting Dialogic DTI/212 E-1 Modules (75-Ohm)

The Dialogic DTI/212 E-1 modules come in 75-ohm and 120-ohm versions. If you have a DTI/212 120-ohm module, see Section 2.4.1.1.3. Refer to the Dialogic Network Hardware Reference for additional information on DTI/212 E-1 modules.

On the rear bracket of the DTI/212 75-ohm module are two BNC-type jacks for connecting to the external E-1 network. The cabling between these jacks and the external E-1 network should be 75-ohm coaxial. The DTI/212 end of the cable should consist of a BNC-type male connector. The user is responsible for supplying an appropriate cable for these connections. The pin designations for the DTI/212 75-ohm cable ends are given in Table 2-3.

Table 2-3: E-1 to DTI/212 75-Ohm Pin Designations

Signal

Jack/Pin

Transmit data: output from DTI/212 (tip)

J201A center

Transmit data: output from DTI/212 (ring)

J201A shield

Receive data: input to DTI/212 (tip)

J201B center

Receive data: input to DTI/212 (ring)

J201B shield

 

 

To cable the DTI/212 75-ohm module to the E-1 network, follow these steps:

1.Attach the appropriate end of the E-1 to DTI/212 (receive) cable to jack J201B on the rear bracket of the DTI/212 module. Carefully push the BNC connector onto the jack and lock by turning a quarter-turn clockwise.

2.Attach the appropriate end of the DTI/212 to E-1 (transmit) cable to jack J201A on the rear bracket of the DTI/212 module. Carefully push the BNC connector onto the jack and lock by turning a quarter-turn clockwise.

2.4.1.1.3 Connecting Dialogic DTI/212 E-1 Modules (120-Ohm)

On the rear bracket of the DTI/212 120-ohm module is an RJ-48C jack for connecting to the external E-1 network. The cabling between this jack and the CSU should be 120-ohm twisted pair or equivalent. The DTI/212 120-ohm end of the cable should consist of an RJ-48C plug. The user is responsible for supplying an appropriate cable for these connections. The pin designations for the DTI/212 120-ohm cable ends are given in Table 2-4.

Table 2-4: E-1 to DTI/212 120-Ohm Pin Designations

Signal

Pin(s)

Receive ring: input to the DTI/212 120-ohm module

1

Receive tip: input to the DTI/212 120-ohm module

2

No connection

3, 6

Transmit ring: output from the DTI/212 120-ohm module

5

Transmit tip: output from the DTI/212 120-ohm module

4

Optional shield

7, 8

 

 

2–6AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide

Image 28
Contents May Compaq Computer Corporation Houston, Texas May Acoustics Page Table of Contents Reconfiguring the AlphaServer IP Platform System TroubleshootingAlphaServer IP Platform Specifications Basic OperationAlarm Input Wiring Field Wiring the -48 Vdc Power InverterAlphaServer IP Platform Duplex System Diagrams AlphaServer IP Platform Simplex System DiagramsViii Preface About This GuideIntended Audience Structure of This DocumentRelated Documentation ConventionsConvention Meaning Introduction Product OverviewIP Platform Overview IP Simplex System IP Duplex SystemFactory Installed Software System Features Alarm SubsystemUser Interfaces MaintainabilitySafety and Electromagnetic Compatibility UpgradingCompaq Computer Corporation and Industry Standards Telecommunications InterfacesAlphaServer 1000A System Required and Optional HardwareSystem Security OverviewAlphaServer 1000A Required Hardware Part Number Description Simplex DuplexModular Storage Shelf Subsystem BA35x-Sx ISA Bus Expansion ChassisModular Storage Shelf Optional Hardware Modular Storage Shelf BA35x-Sx Optional HardwareISA Bus Expansion Chassis Required and Optional Hardware Part Number Description Simplex DuplexIP Power Controller Subsystem Alarm Indicator PanelIP Power Controller Options Alarm Indicator Panel OptionsExternal Hardware Options External Hardware OptionsPage Installing the AlphaServer IP Platform Hardware Factory Installed HardwareSite Preparation Preinstallation ConsiderationsAchtung Hardware Installation VorsichtInstalling the IP Platform Connecting the Network HardwareConnecting Dialogic D/240SC-T1 and DTI/211 T-1 Modules Signal PinsT-1 to D/240SC-T1 Pin Designations T1 to DTI/211 Pin DesignationsConnecting Dialogic DTI/212 E-1 Modules 75-Ohm Connecting Dialogic DTI/212 E-1 Modules 120-OhmSignal Jack/Pin E-1 to DTI/212 75-Ohm Pin DesignationsConnecting Dialogic LSI/120 Loop-Start Module LSI/120 Loop-Start 25-Pin DesignationsUser Alarms IP Power ControllerLSI/120 Loop-Start 50-Pin Designations Locking Your System Page Turning on the AlphaServer IP Platform Step I Power Controller Circuit BreakersStep III AlphaServer 1000A System Basic OperationVisual Indicators Basic Operation of the IP Platform Subsystem ComponentsAlarm Indicator Panel Front and Rear View Audible Indicator Replacing Batteries in the Alarm Indicator PanelDry Contacts Dry Contact Relay Functional Specification Power Condition Relay State Critical Major MinorModular Storage Shelf BA35x-Sx Subsystem Voltage Amps Reconfiguring the AlphaServer IP Platform SRM Console Configuration Commands AlphaServer 1000A System ConfigurationsCommand Description ISA Bus Expansion Chassis Configuration Removing and Replacing the Alarm Sensor ModuleModular Storage Shelf BA35x-Sx Subsystem Configuration Removing and Replacing the AT Bus Expansion KitAlarm Indicator Panel Configuration Removing and Replacing the Alarm Indicator ModulePage System Troubleshooting AlphaServer 1000A Subsystem Alarm Indicator PanelISA Bus Expansion Chassis AlphaServer IP Power ControllersModular Storage Shelf BA35x-Sx Subsystem Page AlphaServer IP Platform Specifications Physical DimensionsElectrical Specifications Table A-1 Physical DimensionsSystem Environmental Specifications Table A-3 Environmental SpecificationsOperating/Storage Conditions Nonoperating ConditionsDry Contact Specifications Table A-4 Dry Contact SpecificationsInput Specifications Output SpecificationsCentral Office Compatibility Alarm Input Wiring Alarm Input Wiring DiagramTable B-1 Alarm Control M odule 8-Pin MJ Connector Pinout Wiring User Alarm InputsPin No Signal Field Wiring the -48 Vdc Power Inverter Field Wiring the -48 Vdc Power ControllersInstalling Suitable Field Wiring Field Wiring RecommendationsTable C-1 Field Wir ing Recommendations for Each Power Feed Installing the WiringAlphaServer IP Platform Duplex System Diagrams AlphaServer IP Platform Duplex AC System Figure D-1 IP Platform D uplex AC System Front and Side ViewFigure D-2 IP Platform D uplex AC System Rear View AlphaServer IP Platform Duplex DC System Figure D-3 IP Platform D uplex DC System Front and Side ViewFigure D-4 IP Platform D uplex DC System Rear View Page AlphaServer IP Platform Simplex System Diagrams AlphaServer IP Platform Simplex AC System Figure E-1 IP Platform Simplex AC System Front and Side ViewFigure E-2 IP Platform Simplex AC System Rear View AlphaServer IP Platform Simplex DC System Figure E-3 IP Platform Simplex DC System Front and Side ViewFigure E-4 IP Platform Simplex DC System Rear View Page Glossary Command line interface Console modeDiagnostic program BusEisa Configuration Utility ECU Eisa busEnvironment variables EthernetMAC media access control address Maintenance Operations Protocol MOP sessionLight-emitting diode LED Mass storage deviceRedundant ReliabilityRepeater ServerThinWire StorageWorksSystem disk TelnetIndex Index