These items should be cleaned approximately every six months under normal environmental conditions. Equipment in very dusty or otherwise contaminated areas may require more frequent maintenance.

7 . 3 . 1 . B L O W E R

The blower impeller and motor should be cleaned to prevent build-up of contaminant on both the blower impeller surfaces and on the blower motor. Proper operation of the lamp is dependent on providing adequate cooling air flow. A dirty blower may not provide proper air flow, causing the lamp and lamphouse to operate at temperatures that are higher than intended.

1.Clean loose dirt from blower impeller with vacuum cleaner.

2.Use brush with hot water and suitable detergent to remove dirt that cannot be vacuumed off.

When cleaning the impeller, be careful not to bend the blades or to loosen the balancing weights.

3.Every six months, lubricate blower motor by applying three to four drops of light machine oil to oil holes in motor housing.

7 . 3 . 2 . I G N I T E R

Periodically clean the high voltage terminal and insulator to prevent accumulation of dust or dirt.

7 . 3 . 3 . A I R F L O W I N T E R L O C K S

Periodically check and, if necessary, clean the air flow interlock vanes to remove accumulated dirt.

7.4. ALIGNING LAMPHOUSE WITHOUT ALIGNMENT TOOLS

1.Inspect reflector and lens and clean if necessary.

2.Inspect lamp for dirt or fingerprints. Clean if required.

3.Center lamp adjustments in rear of lamphouse to midpoint of their range.

4.Install lamp in lamphouse.

5.Use ruler to verify that positive end of lamp is centered in reflector from top to bottom and side to side. If not centered, adjust to center position by adjusting the front lamp support.

6.For best results: With ruler, verify that positive end of lamp is centered left to right in reflector within 1/16 in. If not centered, adjust front lamp support to center lamp.

CHRISTIE DIGITAL SYSTEMS

7-3

August 7, 2003

 

Image 33
Contents Digital Systems Christie Digital Systems Table of Contents Warranty List of Figures and Tables Figure A-7 Power Supply Table A-7Page Introduction A R N I N G A U T I O N O T E Protective Clothing Safety Kit Contents Safety PrecautionsV E R L O O K D I R E C T L Y a T T H E L a M P Avoid Fire Hazards Page General Description Page Installation Procedures SLC Xenon Lamp Console Front View SLC Xenon Lamp Console Rear View O O R P a N E L S I R I N G H O O K U P AC Wiring Hook-Ups Alignment and Checkout Procedures Plenum, Top View L i g n m e n t a n d C h e c k o u t P r o c e d u r e s Page Operating the SLC SLC 20 SLC 40, 45 P e r a t i n g t h e S L C X e n o n C o n s o l e Optical Alignment of Xenon Lamp Tilt Adjustment Christie Digital Systems Maintenance and Adjustments Always remove the lamp before cleaning the reflector L O W E R 24 VDC 115 VAC Airflow Troubleshooting for Power Supply Does Not Start TroubleshootingTroubleshooting for Power Supply Output Low or Not Steady Troubleshooting for Lamp Does Not IgniteWarranty Christie Digital Systems Appendix a Figure A-1 Autofocus Assembly Description Part Number Table A-1 Parts List for Autofocus AssemblyFigure A-2 SLC Xenon Lamp Console Front View Blower SLC 40,45 Table A-2 Parts List for SLC Xenon Lamp Console Front ViewFigure A-3 SLC Xenon Lamp Console Rear View Capacitor SLC 40, 45 Table A-3 Parts List for SLC Xenon Lamp Console Rear ViewSLC 20 SLC 40, 45 Table A-4 Parts List for Control Panel Figure A-5 Manual Lamp Adjustment Assembly Table A-5 Parts List for Manual Lamp Adjustment Assembly Figure A-6 Plenum , All Models Top View CXL-16S Table A- 6 Parts List for Plenum, All Models Top ViewFigure A-7 Power Supply Capacitor C1 SLC 40, 45 Table A-7 Power SupplyPage Appendix B Figure B-1 Schematic Diagram for IGA-10 Igniter P/N Figure B-2 Schematic Diagram for IGA-15M Igniter P/N Page Page Figure B-3 SLC 20-CC20, SLC 30-CC25 Console Side View Front View