7 : O p e r a t i n g t h e S L C X e n o n C o n s o l e
These items should be cleaned approximately every six months under normal environmental conditions. Equipment in very dusty or otherwise contaminated areas may require more frequent maintenance.
7 . 3 . 1 . B L O W E R
The blower impeller and motor should be cleaned to prevent
1.Clean loose dirt from blower impeller with vacuum cleaner.
2.Use brush with hot water and suitable detergent to remove dirt that cannot be vacuumed off.
When cleaning the impeller, be careful not to bend the blades or to loosen the balancing weights.
3.Every six months, lubricate blower motor by applying three to four drops of light machine oil to oil holes in motor housing.
7 . 3 . 2 . I G N I T E R
Periodically clean the high voltage terminal and insulator to prevent accumulation of dust or dirt.
7 . 3 . 3 . A I R F L O W I N T E R L O C K S
Periodically check and, if necessary, clean the air flow interlock vanes to remove accumulated dirt.
7.4. ALIGNING LAMPHOUSE WITHOUT ALIGNMENT TOOLS
1.Inspect reflector and lens and clean if necessary.
2.Inspect lamp for dirt or fingerprints. Clean if required.
3.Center lamp adjustments in rear of lamphouse to midpoint of their range.
4.Install lamp in lamphouse.
5.Use ruler to verify that positive end of lamp is centered in reflector from top to bottom and side to side. If not centered, adjust to center position by adjusting the front lamp support.
6.For best results: With ruler, verify that positive end of lamp is centered left to right in reflector within 1/16 in. If not centered, adjust front lamp support to center lamp.
CHRISTIE DIGITAL SYSTEMS | |
August 7, 2003 |
|