Page 5
OpTypeLo

Projector Control

4.1.2 Message Body

The message body has the following structure:

Byte 0

Byte 1

Byte 2

 

Byte 3

Byte 4

 

Byte 5

Operation Type

Function

 

Value

OpTypeLo

0x00

FuncNum_lo

 

0x00

Opval_lo

 

Opval_hi

Table 6

4.1.2.1 Field description

 

Field Name

Field Value

Description

 

Operation Type

OpTypeLo

 

 

0x01

Operation Set. Set current value

 

0x02

Operation Get. Gets the current value

 

0x03

Operation Initialize. Initialize the value to default.

 

 

Should not be used

 

0x04

Operation Increment. Increment the value by one

 

 

step. Only valid for “Adjust” functions.

 

0x05

Operation Decrement. Decrement the value by one

 

 

step. Only valid for “Adjust” functions.

 

0x06

Operation Execute. Execute the operation. Only

 

 

used for “Execute” operations

Function

FuncNum

The actual function number to execute. A list of

 

 

usable FuncNumis given in Chapter 7

Value

-

Only used by Operation Set. The actual value to set

 

 

the operation to. For all other operation actions, this

 

 

field is set to 0x0000.

Table 7

 

 

Page 5

Version 1.0

Image 5
Contents C90/100 Projector ControlVersion REVISEDSETTING UP Projector Control 1 SETTING UP3 FUNCTION TYPE 2 GENERAL4 PROTOCOL MESSAGES 0xBEOperation Type OpTypeLoFunction Value6 TRANSACTION EXAMPLES 5 COMMAND RETURN CODES6.1.4 Example 4 Hex sequence for power on with CRC deactivated 7 TABLE OF FUNCTIONS Version APPENDIX 1 CRC CALCULATION ALGORITHM static const BYTE cCRCLoArray =