Ask Proxima C100, C90 manual Example 4 Hex sequence for power on with CRC deactivated

Page 7
6.1.4 Example 4: Hex sequence for power on (with CRC deactivated)

Projector Control

6.1.3 Example 3: Hex sequence for Set Brightness to 70% => 0.7*255 = 178 = 0xB2

Host:

0xBE 0xEF 0x80 0x06 0x00 0x2E 0x04 0x01 0x00 0x11 0x00 0xB2 0x00

Magic number Body size

CRC

Op.type Function

Value

7byte Message Head

 

6byte Message Body

Projector:

0x06

6.1.4 Example 4: Hex sequence for power on (with CRC deactivated)

Host:

0xBE 0xEF 0x80 0x06 0x00 0x00 0x00 0x01 0x00 0x01 0x00 0x00 0x00

6.1.5 Example 5: Hex sequence for get Brightness

Host: =>

0xBE 0xEF 0x80 0x06 0x00 0xBD 0x70 0x02 0x00 0x11 0x00 0x00 0x00

<= Projector (70%) 0x1D 0x00 0xB2

6.1.6 Example 5: To get ASCII Information Set Parameter in the State String function

Host:Projector Operation Set Packet =>

<=ASCII Strings <= ACK

Page 7

Version 1.0

Image 7
Contents REVISED Projector ControlC90/100 VersionSETTING UP Projector Control 1 SETTING UP0xBE 2 GENERAL3 FUNCTION TYPE 4 PROTOCOL MESSAGESValue OpTypeLoOperation Type Function6 TRANSACTION EXAMPLES 5 COMMAND RETURN CODES6.1.4 Example 4 Hex sequence for power on with CRC deactivated 7 TABLE OF FUNCTIONS Page APPENDIX 1 CRC CALCULATION ALGORITHM static const BYTE cCRCLoArray =