Troubleshooting (continued)

Related Messages (continued)

Message

Description

 

 

CLEAN THE AIR FILTER

A note of precaution when cleaning the air filter.

Please immediately turn the power OFF, and clean or change

POWER OFF FIRST,

the air filter by referring to the “Air Filter” section of this manual.

THEN CLEAN THE AIR FILTER.

After you have cleaned or changed the air filter, please be sure

AFTER CLEANING THE AIR

to reset the filter timer.

FILTER,

If the same message is displayed after the treatment, please

clean the transparent area of filter cover and the dust-detecting

RESET THE FILTER TIMER.

window, according to the following.

 

 

 

ATTENTION • The transparent area of filter cover and the dust-detecting window should be cleaned for normal operation of the optical dust detecting system. Please pay attention not to remain fiber or fragment of cloth inside the duct.

1

 

Turn off the projector, and unplug the

Filter cover

 

power cord.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

After making sure that the projector

 

 

2

 

 

 

 

 

has cooled adequately, remove the

 

 

 

 

filter cover.

 

 

 

 

Hold the release buttons of the filter cover, while

Release buttons

 

 

 

pulling up it.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

Wipe the transparent area of the filter

Filter cover

 

 

 

 

 

cover by using a swab or a soft cloth.

 

Transparent area

 

 

 

Remove the air filter.

 

 

Release buttons

 

4

 

 

 

 

 

 

 

 

 

 

Hold the release buttons of the air filter, while pulling

 

 

 

 

 

 

 

down it.

 

 

 

 

 

 

 

 

 

 

Air filter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wipe the dust-detecting window by

 

 

 

 

 

5

 

 

 

 

 

 

 

 

using a soft cloth.

 

 

 

 

 

 

 

 

 

 

(Rear side)

 

 

 

Dust detecting window

 

 

(Bottom side)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

38

6 Replace the air filter and filter cover.

Image 38
Contents H10 Multimedia Projector Contents Projector Features PreparationAttaching The Base Part NamesProjector Slowly turn the projector so that the top is facing upTo adjust the keystone ProjectorRemote Control Setting Up ArrangementAs necessary, you can also finely Adjusting The Projectors ElevatorAdjust the height of the projector by Twisting the elevator feet by handConnecting Your Devices Connecting to a computer AUDIO-L AUDIO-R G B RConnecting Power Supply Close Battery cover Remote ControlRemove Battery cover Putting BatteriesOperating The Remote Control Make sure that the power cord is Power ON/OFFTurning On The Power Remote controlUse the zoom ring to adjust the screen Size Selecting An Input SignalSelecting a RGB signal Use the focus ring to focus the pictureTurning Off The Power Switch the power switch to O OFFTemporarily Muting The Sound Adjusting The VolumeOperating Press the Position button Adjusting The PositionUse Buttons to adjust Position Using The Automatic Adjustment Feature Correcting Keystone DistortionsFreezing The Screen Using The Magnify FeatureUse Buttons to adjust the zoom Level Press the Magnify on buttonTemporarily Blanking The Screen Signal SearchingSelecting The Aspect Ratio Multifunctional Settings Using The Menu FunctionsMain Menu Picture 1 Menu Picture 1 Menu Load/Save a SettingReset the PICTURE-1 Menu Items LOAD4Position PhasePicture 2 Menu SizeVideo Input MenuColor Space Frame LockInformation Input MenuVideo NR S2-ASPECTSearch AdjustAuto Menu Message Screen MenuStart UP Lamp Time VolumeOption Menu Lamp Replacing The Lamp Caring For The Air Filter Reset the filter timerAir Filter Filter, while pulling down it Replacing The Air FilterHold the release buttons of the air Filter coverCaring For The Inside Of The Projector Caring For The Cabinet And Remote ControlOther Care Caring For The LensTroubleshooting Related MessagesRelated Messages Regarding The Indicator Lamps Power Lamp Temp DescriptionRegarding The Indicator Lamps IndicatorPhenomena That May Easily Be Mistaken For Machine Defects Phenomena That May Easily Be Mistaken For Machine Defects RGB Input Ports Audio Ports SpecificationsSpecification Video Input PortsHow to Order AccessoriesAccessories ……………………………………………………… Part Number Not Included with Basic Packet ………………………………… Part NumberDN00671 H10OGENG

H10 specifications

The 3M H10 series represents the pinnacle of head protection technology, designed to meet the rigorous demands of various industries while prioritizing user comfort and safety. With a focus on innovative features, the H10 combines advanced materials and engineering to deliver exceptional performance in protective headgear.

One of the standout features of the 3M H10 is its robust construction. Made with high-quality polycarbonate material, the helmet is lightweight yet highly durable, ensuring that it can withstand the rigors of industrial environments. Its impact-resistant design not only protects against falling objects but also enhances user safety during potentially hazardous operations.

The H10 series incorporates 3M’s proprietary Comfort System, which significantly improves wearability. The helmet is fitted with a moisture-wicking liner that actively draws perspiration away from the skin, allowing for extended use without discomfort. The adjustable suspension system provides a customized fit, accommodating various head sizes and promoting stability. This ensures the helmet remains securely in place, increasing protection while allowing for easy movement.

Another important characteristic of the H10 is its versatility. The helmet is compatible with a range of 3M attachment accessories, such as visor mounts, hearing protection, and communication devices, making it suitable for diverse applications, from construction and manufacturing to logging and mining. This adaptability enhances its functionality, offering users an all-in-one solution for head protection and additional safety measures.

In addition to these features, the 3M H10 is designed with ventilation in mind. Thoughtfully placed vents allow for optimal airflow, reducing heat buildup during long periods of wear. This attention to comfort is crucial, especially in warm weather conditions or during physically demanding tasks.

Moreover, the 3M H10 series is compliant with international safety standards, ensuring that it meets or exceeds the expected performance criteria for head protection. This commitment to quality provides peace of mind for both employers and employees, knowing that they are protected with some of the best technology available in the market.

In conclusion, the 3M H10 series exemplifies the intersection of safety, comfort, and versatility in head protection. With its durable materials, user-friendly design, and compatibility with accessories, the H10 stands out as a reliable choice for various industries, promoting safety without compromising comfort. As workplaces continue to prioritize employee well-being, the 3M H10 series is a vital investment in ensuring a safer working environment.