A.8 Serial Inferface Command Codes (continued)
Function | Code | Meaning |
|
IR receiver selection | Write Codes |
|
|
| D5AW00 | Selects Front and Rear IR Receiver | |
| D5AW01 | Selects Front IR Receiver | |
| D5AW02 | Selects Rear IR Receiver | |
| Read Codes | Returns: |
|
| D5AR | ||
|
| ||
|
| ||
|
|
|
|
Magnify | Write Codes |
|
|
| D5BW00 |
|
|
| D5BW01XY to | 01:x1, 02:x2, 03:x4, 04:x8, 05:x16, 06:x32, 07:x64 | |
| D5BW07XY | XYdenotes magnifying portion (00 to FF) | |
| Read Codes |
|
|
| D5BR | 00 – Off |
|
|
| 01 to 07 |
|
|
|
|
|
PIP | Write Codes |
|
|
| D5CW00 | Off |
|
| D5CW01 | ON1 |
|
| D5CW02 | ON2 |
|
| D5CW03 | Refreshes the background for ON1 | |
| Read Codes | Returns: |
|
| D5CR | 00 – Off |
|
|
| 01 – ON1 |
|
|
| 02 – ON2 |
|
Lamp Timer Reset | Write Codes |
|
|
| D60W00 | Resets the lamp timer | |
| Read Codes | Returns: |
|
| D60R | ||
Temperature | Read Codes | Returns: |
|
| D61R | Shows the status of internal temperature | |
|
| level 0 | |
|
| level 1 | |
|
| level 2 | |
|
| level 3 | |
|
| level 4 (Warning) | |
|
| level 5 (Power Off) | |
|
|
|
|
Error Status | Read Codes | Returns: |
|
| D01R |
| |
|
| ||
|
|
| |
|
| ||
|
|
| |
|
|
| |
|
| Note: If there is more than one error, the resulting read code will be the sum | |
|
| f the error codes listed above. Example: For | |
|
| resulting read code is 03. | |
|
|
|
|