A.6 Indicator Status
The POWER, LAMP and TEMP indicators will light or blink in the following cases:
POWER | LAMP | TEMP | MEANING | REMEDY |
INDICATOR | INDICATOR | INDICATOR |
|
|
|
|
|
|
|
Lights orange | Turns off | Turns off | Standby mode | Normal |
|
|
|
|
|
Flashes green | Turns off | Turns off | During warm up | Normal |
|
|
|
|
|
Lights green | Turns off | Turns off | During operation | Normal |
|
|
|
|
|
Flashes orange | Turns off | Turns off | During cooling down | Normal |
|
|
|
|
|
Lights red | Lights red | Turns off | Lamp does not light | Turn off power and let |
|
|
|
| projector cool for 45 minutes. |
|
|
|
|
|
Lights red | Flashes red | Turns off | Lamp or lamp cover | Fully insert lamp module or |
|
|
| loose or missing. | lamp cover and secure with |
|
|
|
| retaining screws. |
|
|
|
|
|
Lights red | Turns off | Flashes red | Cooling fan not | Contact your dealer. |
|
|
| operating. |
|
|
|
|
|
|
Flashes red | Flashes red | Turns off | The lamp operating | Replace the lamp. |
|
|
| hours have reached |
|
|
|
| maximum operating |
|
|
|
| hours. |
|
|
|
|
|
|
*When the LAMP indicator lights or blinks, turn the power off. If the problem persists, contact your dealer.
TECHNICAL
3M™ Multimedia Projector MP8745 | © 3M 1999 |