TROUBLESHOOTING (continued)
Indicators Message
The POWER indicator, LAMP indicator, and TEMP indicator are lit and blank as follows. Take the appropriate measures.
Table 9. Indicators Message
POWER | LAMP | TEMP | Contents | |
indicator | indicator | indicator | ||
| ||||
|
|
|
| |
Lights | Turns off | Turns off | The Standby mode has been set. | |
orange | ||||
|
|
| ||
|
|
|
| |
Blinks | Turns off | Turns off | Warming up. Please wait. | |
green | ||||
|
|
| ||
|
|
|
| |
Lights | Turns off | Turns off | ON. Normal operation possible. | |
green | ||||
|
|
| ||
|
|
|
| |
Blinks | Turns off | Turns off | Cooling. Please wait. | |
orange | ||||
|
|
| ||
|
|
|
| |
|
|
| Lamp is not lit. | |
Lights | Lights |
| The interior of the equipment may be too hot. Switch | |
Turns off | power OFF, wait 20 minutes until the equipment cools, | |||
red | red | |||
| and Switch power ON again. Replace the lamp if the | |||
|
|
| ||
|
|
| same problem occurs. | |
|
|
|
| |
|
|
| Lamp or lamp cover is not found, or hasn’t been fitted in | |
|
|
| correctly. | |
Lights | Blinks | Turns off | Switch power OFF, and wait for 45 minutes until the | |
red | red |
| equipment cools. Check fitting of the lamp and lamp | |
|
|
| cover, and switch power ON again. Contact your dealer if | |
|
|
| the same problem occurs again. | |
|
|
|
| |
|
|
| The cooling fan is not operating. | |
Lights |
| Blinks | Switch power OFF, and wait for 20 minutes until the | |
Turns off | equipment cools. Check for foreign matters in the fan, | |||
red | red | |||
| and switch power ON again. Contact your dealer if the | |||
|
|
| ||
|
|
| same problem occurs again. | |
|
|
|
| |
|
|
| The interior of the equipment is too hot. *1) | |
|
|
| Switch power OFF, and wait for 20 minutes until the | |
Lights |
| Lights | equipment cools. Check whether the ventilation openings | |
Turns off | are blocked, whether the air filter is dirty, or whether the | |||
red | red | |||
| ambient temperature exceeds 35 °C. Then switch power | |||
|
|
| ||
|
|
| ON again. Contact your dealer if the same problem | |
|
|
| occurs again. | |
|
|
|
|
*1) When the internal temperature becomes excessive power is switched OFF automatically for safety reasons, and the indicator is extinguished. Set the power switch to [O] and wait for 20 minutes until the equipment has cooled sufficiently.