| Controlling the Multiple Product | |||
|
|
|
|
|
|
|
Transmission / Receiving Protocol
18.Off Timer On/Off (Command : f c)
► Set days for Off Timer.
Transmission | Acknowledgement |
[f][c][][Set ID][][Data1][Data2][Cr]
[Data1]
0 (Write), FFH(Read)
[Data2]
00 H to FFH
bit0 : Monday Off Timer On(1), Off(0)
bit1 : Tuesday Off Timer On(1), Off(0)
bit2 : Wednesday Off Timer On(1), Off(0)
bit3 : Thursday Off Timer On(1), Off(0)
bit4 : Friday Off Timer On(1), Off(0)
bit5 : Saturday Off Timer On(1), Off(0) bit6 :Sunday Off Timer On(1), Off(0) bit7 : Everyday Off Timer On(1), Off(0)
19.On Timer Time(Command : f d)
► Set On Timer.
Transmission
[c][][Set ID][][OK/NG][Data1][Data2][x]
Acknowledgement
[f][d][][Set ID][][Data1][Data2][Data3][Cr]
[Data1]
0 : Monday
1 : Tuesday
2 : Wednesday
3 : Thursday
4 : Friday
5 : Saturday
6 : Sunday
7 : Everyday [Data2]
00 H to 17 H : 00 to 23 Hours [Data3]
00 H to 3 BH : 00 to 59 Minutes
[b][][Set ID][][OK/NG][Data1][Data2][Data3][x]
*When reading data, FFH is inputted for [Data1], [Data2] and [Data3].
In other cases, all are treated as NG.
A8