Lamp replacement
The lamp is designed to project the image on the LCD panels. When the lamp no longer functions, replace it with a new one.
Caution:
7. Put the handle back to the holding point.
• Make sure that the |
handle is locked. |
8. Tighten up the screws (a) |
ENGLISH
• Do not remove the lamp immediately after turning |
off the lamp of the projector, you may get burned |
because of the high temperature of the lamp. |
using a phillips screwdriver
(+).
(a)
• For lamp replacement, press the power button to |
power off, then wait for 60 seconds in |
to allow the lamp and LCD panels to cool. Then turn |
off the main switch, unplug the power cord from |
the outlet, and wait one hour so that the lamp is |
cooled to the touch. |
• Do not remove the lamp except for replacement. |
Careless treatment can cause injury or fire. |
• Do not touch the lamp element directly. It may break |
and cause you to injure or burn yourself. |
• Be sure not to drop the lamp lid screw into the pro- |
jector. Also be sure not to insert metal or any flam- |
mable objects, it may cause fire or electric shock. If |
any objects are inserted, please unplug and contact |
your dealer. |
• Install the lamp securely, failure may cause a fire. |
1.Reverse the projector gently.
2.Loosen the screws of the lamp lid on the top cover using a phillips screw-
driver (+) , and remove the lid.
•Remove the lamp cover in the direction of the arrow as indicated.
3. Loosen screws (a) using a phillips screwdriver (+).
4. Pull up the handle.
5. Hold onto the projector by the handle as you pull out the lamp.
•Pull out the lamp straight upward.
• Once the lamp has been re- moved, do not spill liquid on it, place it near flam- mable objects or where children can touch it. Otherwise, it will cause injury or fire.
6. Insert the new lamp se- curely into the projector body in the right direc- tion.
•Make sure that the two positioning bosses (b) fit to the lamp positioning holes before inseting the lamp.
9. Tighten up the screws of the lamp lid using a phillips screwdriver (+).
How to reset the operation time meter
Plug in the power cord, switch on the projector, and reset lamp time by pressing the $, % and POWER buttons simultaneously.
Caution:
•Do not spill liquid on the lamp or place it near flam- mable objects or where children can touch it. Oth- erwise, it could cause injury or fire.
•Be sure that the projector guide is firmly inserted between the right and left lamp guides.
Important:
•The projector will not turn on if you do not secure the lamp lid.
•You must reset the operation time meter after you replace the lamp.
•Do not reset the operation time meter unless the lamp has been replaced.
Interval of the lamp replacement
The interval of the lamp replacement about 2,000 hours of consecutive use. Replacement span may differ ac- cording to operating environment, and may be shorter than 2,000 hours. Decreases in luminescence and/or color brightness will indicate that the light source lamp needs to be replaced. When lamp operation time ex- ceeds 1,500 hours, the indicator will flash alternately between green and red (while the lamp is in operation; when the lamp is not in operation, the indicator will appear red only). When the lamp has been used for about 1,900 hours, the message “LAMP!!.” will appear on the screen for one minute. When the lamp has been used for about 2,000 hours, the projector will automati- cally shut off for the safety of the lamp and the power indicator light will be red. The projector cannot be used until the lamp has been replaced and operation timer has been reset.
Caution:
•The lamp is fragile. If broken, be careful not to cut yourself with glass fragments.
•The replacement span of the lamp depends on the environment. For replacement lamps, please con- tact your dealer.
The projector automatically shuts off af- ter about 2,000 hours, and you cannot use the projector until you replace the lamp.
EN – 23