Lamp replacement
The lamp is designed to project the image on the LCD panels. When the lamp no longer functions, replace it with a new one.
Caution:
•Do not remove the lamp immediately after using the projector, you may get burned because of the high temperature of the lamp.
•When you replace the lamp, press the power button to power off, then wait for 120 seconds in
•Do not remove the lamp except for replacement. Careless treatment can cause injury or fire.
•Do not touch the lamp element directly. It may break and cause you to injure or burn yourself.
•Be sure not to drop the lamp lid screw into the pro- jector. Also be sure not to insert metal or any flam- mable objects, it may cause fire or electric shock. If any objects are inserted, please unplug and contact your dealer.
•Install the lamp securely, failure may cause a fire.
1. Reverse the projector gently.
2. | Loosen the screws of the | Screw of the lamp lid | |
| lamp lid on the top cover us- |
|
|
| ing a phillips screwdriver |
|
|
| (+) , and remove the lid. |
|
|
• | Remove the lamp cover in |
|
|
| the direction of the arrow |
|
|
| as indicated. |
|
|
3. | Loosen screws (a) using a phillips | (a) | |
| |||
| screwdriver (+), and remove them. |
|
Handle
4. Hold onto the projector by the handle as you pull out the lamp.
Once the lamp has been removed, do not spill liquid on it, place it near flammable objects or where children can touch it. Otherwise, it will cause injury or fire.
5. Insert the new lamp securely into the projector body in the right direction.
6. Tighten up the screws (a) using a |
|
|
|
| (a) |
phillips screwdriver (+). |
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
|
|
7. Tighten up the screws of the lamp
lid using a phillips screwdriver
(+).
How to reset the operation time meter
Plug in the power cord, switch on the projector, and reset lamp time by pressing the $, % and POWER buttons simultaneously.
Important:
•If the 3 buttons was not pressed at the same time, the lamp time may not be reset.
•Please confirm the TEMP indicator illuminates about 2 seconds and the lamp time has been reset.
•The projector will not turn on if you do not secure the lamp lid.
•You must reset the operation time meter after you replace the lamp.
•Do not reset the operation time meter unless the lamp has been replaced.
Caution:
•Do not spill liquid on the lamp or place it near flam- mable objects or where children can touch it. Oth- erwise, it could cause injury or fire.
•Be sure that the projector guide is firmly inserted between the right and left lamp guides.
The life of the lamp
The average life of the lamp for the projector is about 2,000 hours of consecutive use. Life span may differ according to operating environment, and may be shorter than 2,000 hours. Decreases in luminescence and/or color brightness will indicate that the light source lamp needs to be replaced. When lamp operation time ex- ceeds 1,500 hours, the indicator will flash alternately between green and red (while the lamp is in operation; when the lamp is not in operation, the indicator will appear red only). When the lamp has been used for about 1,900 hours, the message “LAMP!!.” will appear on the screen for one minute. When the lamp has been used for about 2,000 hours, the projector will automati- cally shut off for the safety of the lamp and the power indicator light will be red. The projector cannot be used until the lamp has been replaced and operation timer has been reset.
Caution:
•The lamp is fragile. If broken, be careful not to cut yourself with glass fragments.
•The lamp life depends on the environment. For re- placement lamps, please contact your dealer.
The projector automatically shuts off af- ter about 2,000 hours, and you cannot use the projector until you replace the lamp.
EN – 22