Mitsubishi Electronics FX0N-232ADP manual Start

Page 10

 

Start

Is power

LED lit?

 

YES

Is M8063

turned on?

No send

NO

or receive

error

 

Only receiving fails to operate normally

NO

Is send

wait flag M8121

turned on?

NO

Is SD LED

(send) lit up momentarily?

YES

Is the send

data remainder

zero?

YES

 

NO

Check connection with the PC.

 

 

 

 

• Check power source of PC.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

The data

NO

Match the communication format.

 

transfer

Check the wiring of control line.

 

 

 

 

 

Send,

complates

 

 

 

Check the start timing of send, receive.

 

receive

once.

 

 

error

 

 

 

 

No send

or receive error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

There is a possibility of send crosstalk. Check the send and receive

 

 

 

 

YES

 

timing with the external RS232C device.

 

 

 

 

The receive data length may exceed the receive data area.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check the receive data length and timing of receive start.

 

 

 

 

 

 

Check that the program is not set so that M8122 may be always on .

 

 

 

 

 

 

 

 

 

 

 

YES

1

• Check wiring of control line. YES • Check timing of send, receive.

Change RS instruction from OFF to ON.

Make sure the received data length matches with the receive data area length.

NO • Check wiring of RS232C cable.

Check wiring of control line.

Make sure the receiving external device is normal.

Check the voltage level of RS232C signal (±9 V).

Make sure content of send data and communication format are established before driving RS instruction.

NO

• Check the timing of control line.

Check the wiring of RS232C cable.

Check the wiring of control line.

Match the communication format.

Make sure the receiving external device is normal. (CR, LF may be needed in some printers.)

Check the data format of sending device.

Image 10
Contents Users Guide Terminal Layouts IntroductionRS232C device Performance specification Installation Notes and UsageGeneral specification Communication format D8120 bit mapping Wiring Connection examplesProgram Examples Sequence program OperationPreparation of software RS instruction drive Turn on X000, and drive RS instruction Diagnostics Start When M8123 is reset, the PC returns to the wait state Manual number JY992D51301 Manual revision C Date June