CONNECTIONS
SETTING MODE SWITCHES
SETTING MODE SWITCHES
Set the mode switches on the rear panel according to the equipment connected. All the switches are set to OFF as shown right when shipped from the factory. Turn off the power when changing the mode switch settings.
With the switch No.1 and No. 2, the printing speed can be set.
Switch No. | Print speed | ||
1 | 2 | ||
| |||
OFF | OFF | Prints at the speed set by the printer driver | |
ON | ON |
| |
OFF | ON | FINE mode print | |
ON | OFF | FAST mode print |
With the switch No.3 to No. 8, the following can be set.
8 7 6 5 4 3 2 1
OFF
ON
Switch No. | Settings | Functions |
3 | OFF | Uses the normal gamma curve of images |
| ON | Uses the gamma curve for connecting to ultrasound diagnostic equipment |
4 | OFF | Normal print |
| ON | Mirror print |
5 | OFF | Prints with surface coating |
| ON | Prints without surface coating |
6 | OFF | Not used (Set this switch to OFF.) |
7 | OFF | When the printed paper remains at the print outlet, PAPER indicator blinks and this unit stops printing. |
| ON | Even if the printed paper remains at the print outlet, PAPER indicator remains turned off and this unit |
|
| does not stop printing. |
8 | OFF | Automatic feed&cut mode |
|
| This will cause the printer to perform an automatic feed and cut after installation of the paper and ink |
|
| sheet. |
| ON | Manual feed&cut mode |
|
|
|
10