InFocus W61, W60, RS232, IN5124, IN5122 manual Read Command Examples

Page 15

Command Control via the Network (continued)

A write request example:

(AAA####) where (starts the command

AAA denotes the command

####denotes the value to be written

(leading zeros not necessary) ) ends the command

Some commands have ranges, while others are absolute. If a number greater than the maximum range is received, it is automatically set to the maximum number for that function. If a command is received that is not understood, a "?" is returned. With absolute settings, "0" is off, 1-9999 is on. The one exception is the Power command, where 0 is off and 1 is on.

To assure the projector can process a command, wait 3 seconds before entering the next command.

Read Command Examples

Function

Command

Response

Brightness

(BRT140)

Sets the brightness to

 

 

140

Power

(PWR0)

Turns power on

Power

(PWR1)

Turns power off

Error Conditions

Not all commands are supported for all projectors. If an unsupported command is issued, the command will be ignored. If a command is received that is not understood, a ‘?’ character will be returned indicating the command was not understood.

Limitations

The projector cannot respond to commands coming in at a high-rate. Therefore, a delay must occur between commands to ensure that the command gets properly executed. To assure the projector can process a command, wait 3 seconds before entering the next command.

The Step column refers to increasing or decreasing the menu bar position since the On-screen Display is not an exact match of values. For example, Step 2 changes the data by 2 through the CLI (Command Line Interface). The menu bar is up (or down) by 1.

13

Image 15
Contents 010-0763-00 This page left blank intentionally IN5122/IN5124 IN5122 Computer Mode Table IN5124 Computer Mode Table Computer IN1, B Monitor OUT Connection to the portsVideo SCL SDACEC USB Type a To input Scart RGB signal RS-232 Communication Connection LAN Command Control via the NetworkCommunication Port RS-232 Commands Read Command Examples Network Bridge Communication Communication settings Basic Menu RS-232 Communication / Network command tableAdvanced Menu GTP GTBRG3 TMPRG1 RG2RF3 BG6RF1 RF2Input Menu ImageMenu Setup SG1SG2 SM2 SPSSM0 SM1Advanced Menu Audio SA3 SA0SA1 SA2Advanced Menu Screen SR1 AOTUSB EFKAdvanced Menu Option Service Advanced Menu Security Advanced Menu Other Infocus Unique PJLink command Lamp ?
Related manuals
Manual 54 pages 4.79 Kb Manual 89 pages 6.49 Kb