4Push the 2 tabs on the lamp door toward the front of the projector and lift the lamp door off.
5Loosen the three captive screws that attach the lamp housing to the pro- jector.
6Detach the lamp connector from the projector by depressing the locking tab on the connector and lightly pulling it free.
WARNING:
To avoid burns, allow the projector to cool for at least 60 minutes before you replace the lamp.
Be extremely careful when removing the lamp housing. In the unlikely event that the bulb ruptures, small glass fragments may be generated. The lamp housing is designed to contain these frag- ments, but use caution when removing the lamp housing. Before replacing the lamp, clean the lamp compartment and dispose of cleaning materials. Wash hands after lamp replacement.
Hg – Lamp contains mercury. Manage in accordance with local disposal laws. See www.lamprecycle.org.
7Carefully remove the lamp housing. Dispose of the lamp in an environ- mentally proper manner.
8Install the new lamp housing and tighten the screws.
9
lamp door
captive screws
lamp housing
lamp connector