Loop Out setting
When this feature is set to ON, the received signal will be looped out.
Example: Setting “ON”
Set “ADVANCED OSM” to “ON” in the main menu (1/ 2), then perform the following operations.
1.On the MAIN MENU, select “OPTION3”, then press the MENU/ENTER button.
The “OPTION3” screen appears.
2.Use the ▲ and ▼ buttons to select “LOOP OUT”.
3.To set the LOOP OUT to “ON”...
Use the ◀ and ▶ buttons to select “ON”.
The mode switches as follows each time the ◀ or ▶ button is pressed:
OFF ↔ ON
|
|
|
| OPTION3 |
| 3 / 3 | |
|
| PREVIOUS PAGE |
|
|
| ||
TIMER |
|
|
|
| |||
PWR. ON MODE |
| : | LAST | ||||
CONTROL LOCK |
| : | OFF | ||||
IR REMOTE |
| : | ON | ||||
| LOOP OUT |
|
| : | ON | ||
|
|
|
|
|
|
| |
ID NUMBER |
| : | ALL | ||||
VIDEO WALL |
|
|
|
| |||
|
| SEL. | ADJ. |
| EXIT | RETURN |
Information
⬛LOOP OUT settings
ON ...... The received signal will be looped out via PC1
terminal or VIDEO1 terminal.
OFF .... The received signal will not loop out.
*Even if LOOP OUT is ON, signals won’t be sent out if POWER is being turned off.
⬛To connect another display...
See page 10.
⬛If the RGB/PC1 signal is present at the time the power switched on...
The RGB/PC1 input will be displayed regardless of the setting of LOOP OUT.
⬛Restoring the factory default settings
Select “ALL RESET” under the OPTION1 menu. Note that this also restores other settings to the factory defaults.
ID number setting
When using more than one of these displays, this function sets ID numbers so that operation of the remote control does not cause multiple monitors to operate at the same time.
Example: Setting “2”
Set “ADVANCED OSM” to “ON” in the main menu (1/ 2), then perform the following operations.
1.On the MAIN MENU, select “OPTION3”, then press the MENU/ENTER button.
The “OPTION3” screen appears.
2.Use the ▲ and ▼ buttons to select “ID NUMBER”.
3.To set the ID NUMBER to “2”...
Use the ◀ and ▶ buttons to select “2”.
The mode switches as follows each time the ◀ or ▶ 35
button is pressed:
→ALL ↔ 1 ↔ 2 ↔ ..... ↔ 255 ↔ 256←
|
|
|
| OPTION3 |
| 3 / 3 | |
|
| PREVIOUS PAGE |
|
|
| ||
TIMER |
|
|
|
| |||
PWR. ON MODE |
| : | LAST | ||||
CONTROL LOCK |
| : | OFF | ||||
IR REMOTE |
| : | ON | ||||
LOOP OUT |
| : | OFF | ||||
| ID NUMBER |
|
| : | 2 |
| |
|
|
|
|
|
|
| |
VIDEO WALL |
|
|
|
| |||
|
| SEL. | ADJ. |
| EXIT | RETURN |
*To reset back to ALL Press the CLEAR button.
Information
⬛ID NUMBER settings
ALL ........... ID NUMBER will not be set.
1 to 256 .... ID NUMBER will be set.
⬛When the ID NUMBER have been set
You can also set ID NUMBER for each remote control to operate the plasma display individually. To do so, see below.
⬛Restoring the factory default settings
Select “ALL RESET” under the OPTION1 menu. Note that this also restores other settings to the factory defaults.
To set the ID number for the remote control
Example: Setting “2”
1.Press the ID SELECT button on the remote control. The “ID SELECT” screen appears.
2.Use the ▲ and ▼ buttons to select “ID NUMBER”.
3.To set the ID NUMBER to “2”...
Use the ◀ and ▶ buttons to select “2”.
The mode switches as follows each time the ◀ or ▶ button is pressed:
→ | ALL ↔ 1 ↔ 2 ↔ | ..... ↔ 255 ↔ 256← |
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ID SELECT |
|
|
|
|
|
|
|
|
| POSITION : | 1 |
|
|
|
|
| ID NUMBER |
| : | 2 |
|
|
| |
|
|
|
|
|
| ||||
|
|
|
|
| ADJ. |
| RETURN | ||
|
|
|
|
| EXIT |
*To reset back to ALL Press the CLEAR button.
4.Once the setting is completed...
Press the EXIT button to delete the ID SELECT screen.