Hasselblad Flextight 343 manual Replacing the Light Tube, Follow procedure below to replace a tube

Page 17

Hardware Reference - Flextight 343

17

The Light Tube

 

Replacing the Light Tube

If your scans are suddenly coming out black (or all white if you are scanning negatives), then the light tube may be defective or misaligned.

Follow procedure below to replace a tube:

1.Get the appropriate replacement light tube (ask your Flextight dealer or see specification in “Technical Specifications” on page 20).

2.Turn off and unplug the scanner from the primary power supply.

3.IMPORTANT: Let the light tube cool down for app. 10 minutes before proceeding.

4.Lay the scanner down on its back, with the bottom facing you.

5.Use a 2.5 mm allen key to remove the screws located at each of the four corners of the bottom panel (see Figure 6), then remove the bottom panel.

English

1

4

3

2

Figure 6: To remove the bottom panel, remove the four screws at the positions shown. The numbers indicate the order in which they should be tightened when panel is replaced.

continues...

User's Guide - Flextight 343

Image 17
Contents Users Guide Users Guide Flextight Table of Contents English Hardware Reference Flextight System Requirements Front Panel Front panel features of FlextightBack panel features of Flextight Back Panel & ConnectorsCut-away view of Flextight Cut-Away ViewElectrical Requirements Setting up the ScannerEnvironmental Requirements Installation Procedure, FireWire Interface Operating the Flextight 343 scanner Operating the Scanner Original Resolutions PPI Max Resolutions True Optical Resolutions Zoom Setting Original Max Resolution Orientation of the Light Tube Light TubeReplacing the Light Tube Follow procedure below to replace a tubeBottom view of the scanner with the bottom panel removed Disposal Cleaning the External Surface of the ScannerTechnical Specifications FCC Notice Declaration of conformity CE Declaration of Conformity