Lumens Technology VC-G50 quick start 1 RS-422 Pin Description, Use RS-422 Connection

Page 33

7.2RS-422 Connection

7.2.1RS-422 Pin Description

Pin NO.

Function

1

RXD OUT -

2

RXD OUT +

3

TXD OUT -

4

TXD OUT +

5

GND

6

RXD IN -

7

RXD IN +

8

TXD IN -

9

TXD IN +

7.2.2Use RS-422 Connection

1.Hold the two sides of RS-422 connector and pull out in the direction

shown by the arrow in the figure below

2.Peel off a section of copper wire (AWG Nos.28 to18) and insert it into the connector hole; then use flat screw driver to fix it

English - 32

Image 33
Contents Camera Installation Guide English Table of Contents DIP Switch Setting Copyright Information Safety Instructions  FCC Warning  Precautions EN55022 CE Radiation Warning  KCC WarningPackage Contents Description of LED indicator Product OverviewOverview Preparation before installation Instruction for installationInstruction for installation Would like to install VC-G50 on the deskDimension Would like to install VC-G50 on the ceilingSize Diagram Page Bottom of machine English Installation steps Precautions for installationPage How to remove Image output Connecting the deviceConnecting to a Hdtv 3G-SDI Controlling VCs with the computer Functions of remote control Remote Control and Setting MenuSetting menu 0dB Manual GainManual Speed 30dB Gain LimitAuto OffWhite BalanceMode5 Image ModeMode1 LoadTilt Down 30~0 Preset SpeedZoom Limit 150 deg/secStatus Factory ResetWould like to adjust the shooting angle of the lens Would like to switch to VC-G50Would like to save the current lens position data Would like to clear the saved position dataWould like to adjust the focus speed Would like to adjust the focal lengthWould like to freeze images Would like to set the image modeWould like to rotate the image Would like to change the camera directionOutput Switch DIP Switch SettingCamera Address Selector System SwitchRS-422 Connection 1 RS-422 Pin DescriptionUse RS-422 Connection Page Troubleshooting RS-232/RS422