ENGLISH
RS-232C Communication Examples
This section shows the communication examples of RS-232C.
Operating command
Type | Command | Description | |
|
|
| |
Connection check | PC This unit: 21 89 01 00 00 0A | Checks connection | |
This unit PC: 06 89 01 00 00 0A | |||
|
| ||
|
|
| |
Power (On) | PC This unit: 21 89 01 50 57 31 0A | When power is turned on from standby mode | |
This unit PC: 06 89 01 50 57 0A | |||
|
| ||
|
|
| |
Power (Off) | PC This unit: 21 89 01 50 57 30 0A | When power is turned off (standby mode) | |
This unit PC: 06 89 01 50 57 0A | from | ||
| |||
|
|
| |
Input (COMP.) | PC This unit: 21 89 01 49 50 32 0A | When video input is set to component | |
This unit PC: 06 89 01 49 50 0A | |||
|
| ||
|
|
| |
Remote Control | PC This unit: 21 89 01 52 43 37 33 32 45 0A | When the same operation as pressing the | |
(MENU) | This unit PC: 06 89 01 52 43 0A | [MENU] button on the remote control is made | |
|
|
|
Reference command
Type | Command | Description | |
|
|
| |
| PC This unit: 3F 89 01 50 57 0A | When information on | |
Power (On) | This unit PC: 06 89 01 50 57 0A | ||
acquired | |||
| This unit PC: 40 89 01 50 57 31 0A | ||
|
| ||
|
|
| |
| PC This unit: 3F 89 01 49 50 0A | When information on | |
Input | This unit PC: 06 89 01 49 50 0A | ||
acquired | |||
| This unit PC: 40 89 01 49 50 30 0A | ||
|
| ||
|
|
|
Getting Started
Preparation
Basic Operation
Settings
Troubleshooting
Others