Thank you for purchasing this JVC Color Video Monitor. Before using it, read and follow all instructions carefully to take full advantage of the monitor’s capabilities.

SAFETY PRECAUTIONS

In order to prevent any fatal accidents caused by misoperation or mishandling of the monitor, be fully aware of all the following precautions.

WARNINGS

To prevent fire or shock hazard, do not expose this monitor to rain or moisture. Dangerous high voltages are present inside the unit. Do not remove the back cover of the cabinet. When servicing the monitor, consult qualified service personnel. Never try to service it yourself.

WARNING : THIS APPARATUS MUST BE EARTHED.

Improper operations, in particular alternation of high voltage or changing the type of tube may result in x-ray emissions of a considerable dose. A unit altered in such a way no longer meets the standards of certification, and must therefore no longer be operated.

This monitor is equipped with a 3-blade grounding-type plug to satisfy FCC rule. If you are unable to insert the plug into the outlet, contact your electrician.

FCC INFORMATION (U.S.A. only)

CAUTION: Changes or modification not approved by JVC could void the user's authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

Notice (U.S.A. only)

This product utilizes both a Cathode Ray Tube (CRT) and other components that contain lead. Disposal of these materials may be regulated in your community due to environmental considerations. For disposal or recycling information please contact your local authorities, or the Electronics Industries Alliance: <http://www.eiae.org.>

7PRECAUTIONS

Use only the power source specified on the unit.

AC power: 120 V/220-240 V, 50 Hz/60 Hz

DC power: 12 V

Keep flammable material, water, and metal objects away from the unit – especially the interior of the unit.

This unit incorporates high voltage circuitry.

For your own safety and that of your equipment, do not attempt to modify or disassemble this monitor.

There are no user-serviceable parts inside.

7SCREEN BURN

It is not recommended to keep a certain still image displayed on screen for a long time as well as displaying extremely bright images on screen. This may cause a burning (sticking) phenomenon on the screen of the cathode-ray tube. This problem does not occur as far as displaying normal video playback motion images.

7HANDLING

Avoid shocks or vibrations. These may damage the unit and cause it to malfunction.

Do not block the ventilation slots.

Do not expose this unit to high temperatures. Extended exposure to direct sunlight or a heater could deform the cabinet or cause the performance of internal components to deteriorate.

Do not place the unit near appliances generating strong electric or magnetic fields. These can generate picture noise and instability.

Keep the monitor clean by wiping the cabinet and CRT screen with a soft cloth. Do not apply thinner or benzine. These chemicals can damage the finish and erase printed letters. If the unit is excessively dirty, use a diluted neutral cleanser, then wipe away the cleanser with a dry cloth.

2

Image 2
Contents TM-1011G Safety Precautions FCC Information U.S.A. onlyContents Controls and Features Front PanelUnder Scan button DC Indicator lampPower lamp Blue Check buttonRear Panel Power input connectorsPin terminals of the DC in 12 V connector Analog audio signal input/output terminals Audio A, Audio B AC power switchComposite signal input/output terminals Video A, Video B DC switchAbout the Menu Screens MENU/VOLUME control CHROMA/PHASE buttonBasic Menu Operations Buttons for Menu OperationsDisplaying the Menu Screens Menu Operation ProcedureAbout reset About sub menuMain Menu Screens How to Use Main MenuFunctions and Adjustment Range of Items 00 OHow to Use SET-UP Menu SET-UP Menu Screens000 O Color System Selects the color systemHour Meter X100h Port F1 Port F6Status Display Sets the status display 10 O 00 O +1031 O 00 O +31 About the External Control How to Use the External ControlHow to Use the MAKE/TRIGGER Terminal Function of the MAKE/TRIGGER terminalDisplay Functions to be controlled Opening Short-circuiting Functions controlled by the MAKE/TRIGGER TerminalOperation Troubleshooting Self-check Indications Following are not malfunctionsSpecifications Dimensions Front View Side ViewColor Video Monitor