JVC GD V502U, GD-V422U manual Display the Set up Timer screen Press to select

Page 63

PRESENT TIME Setup / Set up TIMER

Set up TIMER

Display the Set up TIMER screen.

1

Press to select

POWER ON Time / POWER OFF Time.

Press to set up

POWER ON Time / POWER OFF Time.

button: Forward button: Back

Set up TIMER

 

 

PRESENT TIME

2 : 30

POWER ON Function

 

Off

POWER ON Time

0 : 00

POWER OFF Function

 

Off

POWER OFF Time

0 : 00

Notes:

Pressing or button once changes POWER ON Time / POWER OFF Time 1minute.

Pressing or button continuously changes POWER ON Time / POWER OFF Time by 15 minutes.

2

Press to select POWER ON Function / POWER OFF Function.

Press to select On.

Set up TIMER

 

 

PRESENT TIME

2 : 30

POWER ON Function

 

On

POWER ON Time

6 : 00

POWER OFF Function

 

On

POWER OFF Time

23 : 15

3 R

Press twice to exit from Setup.

Note:

Timer function will not work unless “PRESENT TIME” is set.

23

Image 63
Contents Instructions Plasma Display MonitorRisk of Electric Shock Do not Open Important Safety Instructions Table of Contents Trademark Credits Attach the ferrite coreIf problems occur during use Safety PrecautionsSet up AC Power Supply CordElectric shocks can result if this is not done Cleaning and maintenanceWhen using the Plasma Display All of the following accessories are manufactured by JVCAccessories Accessories SuppliedRemote Control Batteries Connections SpeakersAC cord fixing PC Input Terminals connection Signal Names for mini D-sub 15P ConnectorCommunication parameters Installing the ferrite core Large sizeCommand Serial Terminals connectionRGB signal R, G, B, HD, VD AC cord connection Power on / OFFPower on / OFF Connecting the AC plug to the Wall OutletBasic Controls NormalViewing Surround button Press to accessOFF Timer button Stand-by on / OFF buttonSettings On-Screen Menu DisplaysAdvanced Duration / Saver Time / Power OFF TimeInput Signal Selection Select the Input SignalSelecting the On-Screen Menu Language Auto Just Mode Picture ExplanationAspect Controls Normal Zoom FullHelpful Hint N / Normalize Normalization Adjusting Picture POSITION/SIZEAdjusting screen Size / Clock PhaseMute Sound AdjustmentPicture Adjustments Auto Standard Cinema DynamicNormal Cool Warm Advanced Settings Present Time Present Time SetupSetup SET UP TimerPower OFF Function SET UP TimerPower on TIME/POWER OFF Time Power OFF TimeNegative / Scroll selection Mode selectionStart setting Screensaver For preventing after-imagesSetup of Screensaver Time Reduces screen after-imagePeak Limit Side BAR Adjust OFF, DARK, MID, Bright OFF Dark MID BrightPress to exit from Screensaver Select the magnification required for the enlarged display Digital ZoomDisplay the Operation Guide Select the area of the image to be enlargedCustomizing the Input labels Reduces power consumptionPress to display Multi Display Setup menu Press to select Setup for Multi DisplayHow to setup Multi Display Multi Display SetupNTSC, PAL, Secam Press to select 2×2, 3×33D Y / C Filter For Ntsc Video images SET UP for Input SignalsComponent / RGB in Select Component RGBColor System / Aspect Auto PulldownIf the image becomes unstable Displays the H Horizontal / V Vertical frequencies Setting RGB sync signalSync FREQ. kHz / V-FREQ. HzCars / Motorcycles TroubleshootingPlasma Display panel Symptoms Check Electrical AppliancesVideo / Component / RGB / PC input signals Applicable input signals for PC Input mini D-sub 15P ∗ MarkPAL60 GD-V422U GD-V502U SpecificationsPage GD-V422U / GD-V502U Plasma Display Monitor Plasma Display Monitor GD-V422PCEINSTRUCTIONS GD-V502PCEPresent Time Setup Green-and-Yellow Earth Important Safety NoticeFor Your SAFETY, Please Read the Following Text Carefully This Apparatus Must be EarthedSetup Do not stick any foreign objects into the Plasma DisplayDo not remove the cover or modify it in any way Clean the power cable regularly to prevent it becoming dusty Accessories Supply Observe the following precautionRequires two R6 batteries Optional Video Input Card insert Slots covered AC cord connectionSDA HD/SYNC SCL GND Ground Signal NameFull Just Norm ZoomButton see Picture button Main Power Button On / Off SwitchRemote control Menu Screen on / OFF Power Indicator Sensor Enter / AspectPicture POS./ Size button SET UP buttonOff Position buttons Digital Zoom see Sound button seePower On / Off and input signal selection Power On / Off and input signal selection To Sound adjust menu see To Picture adjust menu seePower OFF Time Press to access each adjust screen From the unitPress to Setup Power on TimeZoom JustAuto Size Adjusting Picture Pos./ SizeHelpful Hint N / Normalise Normalisation PosNormal DynamicCinema Advanced settings Balance MuteBass TrebleExit Button Can be operated Mute button VOL buttonPresent Time Setup Present Time Setup / Set up TimerSet up Timer Screensaver under On, press the R button Reversal / Scroll selectionWhite bar scroll Image Reversal OffStart Time Finish Time Peak limitSide Panel Adjustment Power management Press to exit from SetupPC MiniD-sub input PC/COMPONENT/RGB/DVD/STB Press to select the Multi Display Setup Press to select 2×2, 3×3 Component Setup for Input SignalsComponent / RGB-in Select 3D Y / C Filter For Ntsc AV imagesPAL Secam Ntsc Colour system / Aspect AutoCinema reality If the picture image becomes unstableSync No Picture No Sound By button on the remote control Input signal can be displayed Signal name Horizontal Vertical ComponentWhen Multi Screen GD-V422PCE GD-V502PCE GD-V422PCE / GD-V502PCE Plasma Display Monitor