Fisher LNS-T01Z manual Lens Replacement and Installation Procedure, Fig-1, Fig-2, Fig-3

Page 7

LENS REPLACEMENT AND INSTALLATION PROCEDURE

Perform the steps

1

to

5

for lens replacement and installation.

UPPER LENS COVER

 

C

 

 

 

1

REMOVE THE LENS COVER. (See figure-1)

1. Remove screws A (2 screws).

2. Pull down the lower lens cover while pushing the part D, then remove it.

3. Remove screws B (2 screws).

4. Remove screws C (2 screws) and remove upper lens cover.

B

D

2

 

D

Fig-1

IN CASE OF MODEL WITHOUT LENS

A

 

LOWER LENS COVER

REMOVE THE COVER PLATE OF THE LENS COVER. (See figure-2)

Remove 2 screws and pull down the plate.

(At the step 4 , insert the light-block sheet in the same position as the removed cover plate has been placed. Two screws are not used.)

Set the light-block sheet, so that the large rounder side is set over the lens.

SCREWS

COVER PLATE

Fig-2

IN CASE OF MODEL WITH LENS

Figure shown inside of the cabinet.

LENS MOTOR

(D)(D)

REMOVE THE LENS. (See figure-3.)

1.Remove the connector “K16B” of the circuit board.

2.Loosen the A, B wire holder and remove the lens motor lead.

3.Remove screws D (4 screws) which fastens the lens and remove the lens.

A

(D)(D)

B

A

LENS

MOTOR LEAD

CONNECTOR “ K16B”

Fig-3

Image 7
Contents レンズ交換・取付作業手順書 梱包には以下の部品が入っています。 ・レンズ本体 ・レンズ取り付けスクリュー 予備2本 ・専用ドライバー ・遮光プレート 取り付け作業上の注意レンズの交換と取り付けかた 遮光プレートを取り付けます。(図5参照) レンズを取り付けます。(図4参照)レンズカバーを取り付けます。(図6参照) Type of the Cabinet and Reference Installation Manual Lens Replacement Installation ProceduresList of Contents Be Sure to Check for SafetyFig-3 Lens Replacement and Installation ProcedureFig-1 Fig-2Fig-5 Fig-4Fig-6